The Tektronix TDS5054 digital phosphor oscilloscope delivers up to 500 MHz Bandwidth, 5 GS/s real-time sample rate, 2 MB record length and 100,000 wfms/s maximum waveform capture rate. This performance, along with a suite of advanced triggers, intuitive user interface, and an open Windows platform, all in a compact bench-top package, provides exceptional value.
Digital phosphor oscilloscopes provide insight into signal behavior by displaying, storing and analyzing complex signals in real-time using three dimensions of signal information: amplitude, time and distribution of amplitude over time. The Tektronix TDS5054 500 MHz, 5GSa/s Oscilloscope delivers fast waveform capture rates, enabled by Tektronix proprietary DPX™ acquisition technology, saving minutes, hours or even days by quickly revealing the nature of faults so sophisticated trigger modes can be applied to isolate them.
| TDS5054 Vertical System |
| Input Channels |
4 |
| Analog Bandwidth (-3 dB) 5 mV/div - 1 V/div |
500 MHz |
| Calculated Rise Time 5 mV/div (typical) |
800 ps |
| Hardware Bandwidth Limits |
150 MHz or 20 MHz |
| Input Coupling |
AC, DC, GND |
| Input Impedance, 1 MΩ |
±1% |
| Input Impedance, 50 MΩ |
±1% |
| Input Sensitivity, 1 MΩ |
1 mV/div to 10 V/div |
| Input Sensitivity, 50Ω |
1 mV/div to 1 V/div |
| Vertical Resolution |
8-bits (>11-bits w/ averaging) |
| Max Input Voltage, 1 MΩ |
±150 V CAT I derate at 20 dB/decade to 9 VRMS above 200 kHz |
| Max Input Voltage, 50 Ω |
5 VRMS with peaks <±30 V |
| DC Gain Accuracy |
1.5% with offset set to 0 V |
| Offset Range, 1 MΩ |
1 mV/div - 99.5 mV/div ±1 V |
| 100 mV/div - 1 V/div ±10 V |
| 1.01 V/div - 10 V/div ±100 V |
| Offset Range, 50 Ω |
1 mV/div - 99.5 mV/div ±1 V |
| 100 mV/div -1 V/div ±10 V |
| Channel-to-channel Isolation Any Two Channels at Equal Vertical Scale |
≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated bandwidth |
| TDS5054 Timebase System |
| Timebase Range |
200 ps/div to 40 s/div |
| Timebase Delay Time Range |
16 ns to 250 s |
| Channel-to-channel Deskew Range |
±75 ns |
| Delta Time Measurement Accuracy |
±(0.30 sample interval) + (15 ppm * reading) |
| Trigger Jitter (RMS) |
8 psRMS (typical) |
| Long Term Sample Rate and Delay Time Accuracy |
±15 ppm over ≥1 ms interval |
| TDS5054 Acquisition System |
| Real-time Sample Rate |
1.25 GS/s |
| Equivalent Time Sample Rate (max) |
250 GS/s |
| Maximum Record Length per Channel with Standard Memory |
100 k |
| With Opt. 1M |
500 k |
| With Opt. 2M |
2 M |
| TDS5054 Acquisition Modes |
| FastAcq Acquisition |
FastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events |
| Maximum FastAcq Waveform Capture Rate |
100,000 wfms/s |
| Sample |
Acquire sampled values |
| Peak Detect |
Captures narrow glitches at all real-time sampling rates |
| Minimum Peak Detect Pulse Width |
<1 ns |
| Averaging |
From 2 to 10,000 waveforms included in average |
| Envelope |
From 2 to 2 x 109 waveforms included in min-max envelope |
| Hi-Res |
Real-time boxcar averaging reduces random noise and increases resolution |
| FastFrame™ Acquisition |
Acquisition memory divided into segments; maximum trigger rate >225,000 waveforms per second |
| TDS5054 Trigger System |
| Sensitivity |
Internal DC Coupled: |
0.35 div DC to 50 MHz increasing to 1 div at rated bandwidth |
| External (auxiliary input): |
400 mV from DC to 50 MHz increasing to 750 mV at 100 MHz |
| Main Trigger Modes: |
Auto, Normal, and Single |
| Trigger Sequences: |
Main, Delayed by time, Delayed by events. All sequences can include separate horizontal delay after the trigger event to position the acquisition window in time |
| Trigger Level Range |
Internal: |
±10 divisions from center of screen |
| External (auxiliary in): |
±8 V |
| Line: |
Fixed at 0 V |
| Trigger Coupling: |
DC, AC (attenuate <60 Hz), HF reject (attenuate >30 kHz) |
| LF reject (attenuate <80 kHz) Noise reject (reduce sensitivity) |
| Trigger Holdoff Range: |
250 ns minimum to 12 s maximum |