Operating Modes
- Self Test
- Automatic Configuration
- T1 Unframed
- T1 D1
- T1 ESF
- T1 SLC Framed
- T1 DID Framed
- FT1 D4 Framed
- FT1 ESF Framed
- T1 Test Loopback
- T1 Line Loopback
- Repeater Test
- DC Measurements
- TDR Measurements
- HDSL Measurements
- SMARTNIU Measurements
Options
- 209OSP-1 - DC Measurements
- 209OSP-2 - TDR Measurements
- 209OSP-3 - Channel Monitor
- 209OSP-4 - Advanced Stress Patterns
- 209OSP-5 - Enhanced ESF
- 209OSP-6 - Smart Loopback/Command Codes
- 209OSP-7 - Fractional T1
- 209OSP-8 - HDSL/ISDN/DDS Measurements
- 209OSP-96 - DLC/DSO Analyzer Lid
|
|
T-BERD Outside Plant
Tester ( T-Carrier Analyzer )
- Copper analysis with DC measurements and graphical TDR
- Combined testing of digital services and circuits - T1, HDSL,
DDS and ISDN
- Rugged NEMA 4X compliant design endures the harsh weather
conditions
- Battery-powered operation allows for field-portable testing
- Reliable testing and proven performance
Specifications
- Input and Output Connectors: WECO 310, 15-pin D, T1 Repeater
Port, 8 pin RS-232, RJ48
- Input Impedance:
- Bridge: 1000 ohm with ALBO
- Term: 100 ohm with ALBO
- DSX-MON: 100 ohm with AGC
- Receive Level
- Bridge or term: +6 dBdsx to -35 dBdsx (T1), +3 dBdsx to -6 dBdsx (T1C)
- DSX-MON: +6 dBdsx to -24 dBdsx (T1), +3 dBdsx to -24 dBdsx (T1C)
- Level Measurement:
- +6.0 dBdsx to -40 dBdsx
- +6 to -6, 0.1 dB resolution
- -6 to -40,
0.5 dB resolution
- Frequency Measurement: 1 Hz resolutions; 5 ppm accuracy
- Transmit Timing Sources: Internal Clock, Recovered Clock
- Line Codes: AMI, B8ZS
- Loopback Codes: CSU, CSU Line (ESF), CSU Payload (ESF), NIU (FAC1, FAC2, FAC3),
NIU Network (ESF), Programmable (3 to 8 bits), Intelligent Repeaters,
HDSL End-Equipment
- DC Measurements:
- Resistance: 10 ohm to 10 Mohm
- Volts DC: 0.5 to 400 VDC
- Simplex Current: 0 to 200 mA
- TDR Measurements:
- Pulse Amplitude: 10.0 V p-p
- Measurement Range: 50 to 10,500 ft
- HDSL Measurements:
- Loop Loss: 0.0 dB to 40.0 db
- Accuracy: ±0.5 dB
- Resolution: 0.1 dB
- Loop Length: 100 to 20,000 ft
- Capacitance: 1500 pF to 323,500 pF
- Power: -40.0 to +13.0 dB
Package Descriptions
- 209OSP-P1 - Mainframe, DC Measurements, TDR Measurements,
Repeater Adapter
- 209OSP-P2 - Mainframe, DC Measurements, TDR Measurements,
HDSL/ISDN/DDS Measurements, Repeater Adapter
- 209OSP-P3 - Mainframe, DC Measurements, TDR Measurements,
Channel Monitor, Advanced Stress Patterns, Enhanced ESF, Smart
loopback/Command Codes, FT1, Repeater Adapter
- 209OSP-P4 - Mainframe, DC Measurements, TDR Measurements,
Channel Monitor, Advanced Stress Patterns, Enhanced ESF, Smart
loopback/Command Codes, FT1, HDSL/ISDN/DDS Measurements, Repeater
Adapter
|