Cable and Antenna Analyzer
The Site Master is a precision analysis tool which measures SWR, Return Loss and Distance-To-Fault (DTF) on both analog and digital transmission lines. Site Master’s DTF and Return Loss (SWR) measurements are accurate and repeatable, even in the presence of RF interference. Thus, small degradations to RF performance can be spotted before more serious damage occurs. For example, loose
connectors and moisture intrusion can be detected before corrosion destroys the cable - saving thousands of dollars in material and re-installation costs. Since sixty to eighty percent of a typical cell site’s problems are caused by problematic cables, connectors and antennas, Site Master pays for itself quickly.
Features
- Distance-To-Fault Measurements
- Accurately Tests RF Transmission Lines and Antennas
- Precision SWR and Return Loss
- Immunity to Live Site RF Interference
- Synthesizer Accurate to 75 ppm
- Internal Memory Saves Up to 40 Traces and 9 Setups
- Software Tools:
- Smith Chart and Distance-To-Fault
- Compare Measurements to Historical Data
Specifications
| Frequency Accuracy |
75 ppm |
| Frequency Resolution |
100 kHz |
| Measurement Range |
1.00 to 65.00 |
| Return Loss Resolution |
0.1 dB |
| Fault Location Resolution (Nominal) |
0.8% of Maximum Range |
| Dynamic Range |
54 dB |
| Directivity (Corrected) Standard Calibration |
35 dB |
| Directivity (Corrected) Precision Calibration |
42 dB |
| Test Port (Type N) |
50 ohms, 75 ohms with adapter |
| Power Output (Nominal) |
9 dBm, 600 - 1200 MHz > +2 dBm, 300 - 600 MHz |
| Typical Immunity to Interfering Signals up to the level of |
+10 dBm |
| Maximum Input (Damage Level) |
+22 dBm |
| Weight |
2.2 lbs. |
| Size |