| Module |
Model |
# of
Channels |
Terminal |
Measurement
Interval |
Universal
Input |
DU100-11 |
10 |
Screw |
0.5 s |
| DU100-12 |
10 |
Clamp |
0.5 s |
| DU100-21 |
20 |
Screw |
2 s |
| DU100-22 |
20 |
Clamp |
2 s |
| DU100-31 |
30 |
Screw |
2 s |
| DU100-32 |
30 |
Clamp |
2 s |
DCV/TC/DI
Input |
DU200-11 |
10 |
Screw |
0.5 s |
| DU200-12 |
10 |
Clamp |
0.5 s |
| DU200-21 |
20 |
Screw |
2 s |
| DU200-22 |
20 |
Clamp |
2 s |
| DU200-31 |
30 |
Screw |
2 s |
| DU200-31 |
30 |
Clamp |
2 s |
DC Current
Input
Modules |
DU300-11 |
10 |
Screw |
0.5 s |
| DU300-12 |
10 |
Clamp |
0.5 s |
Strain
Measurement
Modules |
DU500-12 |
10 |
Clamp |
0.5 s |
| DU500-13 |
10 |
Clamp |
0.5s |
| DU500-14 |
10 |
NDIS |
0.5s |
Pulse
Measurement
Modules |
DU600-11 |
10 |
Screw |
0.5s |
Digital
Input
Modules |
DU700-11 |
10 |
Screw |
0.5s |
Alarm Contact
Output Modules |
DT200-11 |
4 |
Screw |
SPDT(NO-C-NC) |
| DT200-21 |
10 |
Screw |
Make Contact (NO-C) |
|
|
Yokogawa DR232 Desktop Hybrid Recorder
This highly reliable, expandable and economical unit was developed as the next generation hybrid recorder. It also meets a wide range of needs from small scale data logging to multi-point data acquisition.
- Configurable system with many modules and subunits available
- Communications module, DI/DO module or alarm contact output module
- Up to 6 subunits can be connected. One subunit can be installed on the rear panel
- 0 channel, expandable up to 300 channels
- Universal (DC voltage, thermocouple, RTD and contact). DCV/TC/DI dedicated, power monitor, strain, pulse, direct current, (mA) and digital output module.
- Maximum of 500 ms per 300 channels (including the subunit)
- 4 seconds per 300 channels maximum measurement interval
- Raster scan method, 10-color wire dot recording
- Maximum of 300 recording points
- 250 mm effective recording width
- Analog recording interval (fixed, or auto)
- 300 total alarm outputs
- 60 channels computation function
- RJC
- SQR
- ABS
- LOG
- EXP
- CLOG
- TLOG
- Logic (AND, OR, NOT, XOR)
- Relative computation
- Previous data reference
|
| - |
10 to 300 isolated inputs |
| - |
Measurement interval: As low as 0.5 sec. |
| - |
Flexible inputs: DC Voltage, Thermocouples, RTDs, mAmps, AC Voltage/Current, Strain, Pulse |
| - |
Multi-point recorder and data logger in one instrument |
| - |
Optional FDD |
| - |
Optional Features: Alarm outputs, DI/DO, computer interface (RS-232, GPIB, RS-422/485), math functions, report functions |
| - |
Computer control software available |
|
|