Unlock precise RF network analysis capabilities with the Keysight E5071C ENA Vector Network Analyzer. Featuring a broad frequency range of 9 kHz to 20 GHz, adaptable to your specific needs, this instrument caters to a multitude of industries including wireless communication, automotive, semiconductor, and medical.
With a remarkable dynamic range of 123 dB and an output power of up to 10 dBm, the Keysight E5071C ensures comprehensive signal analysis for both manufacturing and R&D applications. Its versatility extends further with the option for upgrades, including sets for time domain analysis, frequency offset, and more, enabling deeper insights into your RF systems.
Tailor your setup with either a 2-port or 4-port test set, offering various frequency ranges and system customizations to align perfectly with your requirements. Experience precision and flexibility in RF network analysis with the Keysight E5071C ENA.
Features
- Wide frequency coverage: 9 kHz to 20 GHz
- Low trace noise: <0.004 dB rms at 70 kHz IFBW
- Wide dynamic range: >123 dB
- Fast measurement speed: 9 msec for 401 points with error correction
- High temperature stability: 0.005 dB/°C
- 2 or 4 ports, plus flexible multiport configuration of up to 22 ports with E5092A
- Built-in VBA programming environment enables high throughput and UI customization
- Powerful analysis and error correction
- Advanced characterization of mixers (such as the vector mixer calibration) and amplifiers with frequency offset mode (optional)
- Advanced characterization of high-speed serial interconnects with enhanced time domain analysis (optional)
- Upgrade are available for all E5071C options at any time
Specifications
IF bandwidth range |
10 Hz - 1.5 MHz |
Frequency |
9 kHz to 4.5 / 6.5 / 8.5 GHz
100 kHz to 4.5 / 6.5 / 8.5 GHz (with bias tees)
300 kHz to 14 / 20 GHz (with bias tees) |
Input frequency |
10 MHz ±10 ppm |
Output frequency |
10 MHz ±7 ppm |
Output level |
0 dBm ±3 dB into 50 Ω |
Output impedance |
50 Ω |
Voltage |
90-264 VAC (Vpeak > 120 V) |
VA |
350 VA max |
Operating temperature |
+5°C to +40°C |
Weight |
18.8 kg - 22.4 kg (41.4 - 49.3 lb.) |
Vibration |
0.5 G maximum, 5 Hz to 500 Hz |
Humidity |
20% to 90% at wet bulb temperature < +40°C |
Altitude |
0 to 4572 m (0 to 15,000 feet) |
Options
E5071C-280 |
2-port Test Set, 9 kHz to 8.5 GHz without Bias Tees |
E5071C-285 |
2-port Test Set, 100 kHz to 8.5 GHz with Bias Tees |
E5071C-480 |
4-port Test Set, 9 kHz to 8.5 GHz without Bias Tees |
E5071C-485 |
4-port Test Set, 100 kHz to 8.5 GHz with Bias Tees |
E5071C-240 |
2-port Test Set, 9 kHz to 4.5 GHz without Bias Tees |
E5071C-245 |
2-port Test Set, 100 kHz to 4.5 GHz with Bias Tees |
E5071C-2K5 |
2-port Test Set, 300 kHz to 20 GHz with Bias Tees |
E5071C-440 |
4-port Test Set, 9 kHz to 4.5 GHz without Bias Tees |
E5071C-4K5 |
4-port Test Set, 300 kHz to 20 GHz with Bias Tees |
E5071C-445 |
4-port Test Set, 100 kHz to 4.5 GHz with Bias Tees |
E5071C-4D5 |
4-port Test Set, 300 kHz to 14 GHz with Bias Tees |
E5071C-465 |
4-port Test Set, 100 kHz to 6.5 GHz with Bias Tees |
E5071C-460 |
4-port Test Set, 9 kHz to 6.5 GHz without Bias Tees |
E5071C-2D5 |
2-port Test Set, 300 kHz to 14 GHz with Bias Tees |
E5071C-265 |
2-port Test Set, 100 kHz to 6.5 GHz with Bias Tees |
E5071C-260 |
2-port Test Set, 9 kHz to 6.5 GHz without Bias Tees |
Additional Software Options |
E5071C-010 |
- Time Domain Analysis Software
- Fully error-corrected time domain reflection or transmission response
- Up to 20,001 point measurement with low-pass or band-pass mode selection
- Gating available to remove unwanted responses
|
E5071C-790 |
- Measurement Wizard Assistant (MWA) Software
- Available for the E5071C and the E5091A/E5092A configurable multiport test set
- For simplifying multiport device measurements
- Easy and fast measurement setup with step-by-step setup wizard
- Measurement connectivity matrix with the multiport test set
- Minimized operating time with calibration wizard
- Automatic text procedure with go/not go limit test
|
E5071C-008 |
- Frequency Offset Mode Software
- Transmission response measurement of devices such as mixers and converters
- Frequency-offset sweep
- Scalar Mixer Calibration (SMC) for accurate conversion loss/gain measurements
- Vector Mixer Calibration (VMC) for phase and group delay measurements
|
E5071C-TDR |
- Enhanced Time Domain Analysis Software
- Real time measurements simultaneously in time domain (TDR/TDT) and frequency domain (S-parameters)
- Eye diagram tests without external bit pattern generator
- Stressed eye diagram analysis
- Impedance analysis
- ESD Robustness
|
Timebase Stability |
E5071C-UNQ |
Standard stability timebase |
E5071C-1E5 |
High stability timebase |
Hard Disk Drive Options |
E5071C-017 |
Removable Data Storage |
E5071C-019 |
Standard Data Storage |
|