Electrostatic discharges either from a human body to any other part or between two different objects can cause persistent disturbances or even destruction to sensitive electronics or controls. ESD 30N is an ESD tester to simulate ESD pulses at higher voltages up to 30kV in both air and contact discharge mode. It therefore satisifies requirements exceeding the EN/IEC 61000-4-2 test levels and complies to automotive test applications.
Features:
-
Test voltage up to 30kV for air and contact discharge
-
Discharges up to 20Hz
-
Easy-to-change R/C-networks and tips
-
Bleed-Off function
-
Measurement of temperature and humidity
-
AC mains supply and DC supply
-
Battery operated
-
AC mains supply and DC supply
Specifications:
|
Test Level |
|
Test voltage |
200V - 30,000V ± 5% for contact discharge
200V - 30,000V ± 5% for air discharge |
|
Resolution |
100V steps |
|
Holding time (AD) |
More than 5s |
|
Mainframe |
|
HV power supply |
Up to 30kV DC |
|
Power supply |
88V - 250V AC
12V - 18V DC |
|
Battery |
Approx. 1 hour operation; Buffer battery is automatically recharged when connected to AC mains supply
|
|
Interface |
USB to control the ESD generator and to download pre-programmed test routines from esd.control
|
|
Output |
|
Contact Discharge Pulse |
As per EN/IEC 61000-4-2; 150pF/330ohm |
|
Rise time |
As per EN/IEC 61000-4-2 Ed.2 0.8ns +/- 25% |
|
First peak current value |
As per EN/IEC 61000-4-2 Ed.2
7.5A ± 15% @2kV
15A ± 15% @4kV
15A ± 15% @4kV
15A ± 15% @4kV |
|
Current value at 30ns |
As per EN/IEC 61000-4-2 Ed.2
4.0A ± 30% @2kV
8.0A ± 30% @4kV
12.0A ± 30% @6kV
16.0A ± 30% @8kV |
|
Current value at 60ns |
As per EN/IEC 61000-4-2 Ed.2
2.0A ± 30% @2kV
4.0A ± 30% @4kV
6.0A ± 30% @6kV
8.0A ± 30% @8kV |
|
Weight |
Approx. 5.1kg (ESD 30N control unit) |
|
Supply voltage |
AC: 88V - 264V, 50/60Hz
DC: 11V - 16VDC |