The UCS 500N5 ultra-compact simulator is the most versatile tester to cover transient and power fail requirements according to international standards (basic and generic standards) and product/product family standards. The UCS 500N5 is the most economic solution for tests during development as well as for full-compliant immunity tests and CE Marking for single phase DUT with the ability to be extended for testing three-phase DUTs by means of an automatically controlled external coupling network up to 100A.
The UCS 500N5 includes everything necessary to conduct fully compliant tests. The power mains supply for the controls and for the DUT is separate to render it more flexible to use with different DUT supply voltages. The UCS 500N5 can be operated manually from the front panel or by remote via the built-in USB or GPIB interface. Fail inputs allow to control an ongoing test sequence based on the status of the DUT. Monitoring outputs (BNC) are offered for easy signal measurement and verification. Safety features such as interlock and warning lamp control are available.
Pre-programmed Standard Test routines allow highest user convenience. Still the UCS 500N5 offers the Quick Start test routine where parameters can be changed on-line during the test to evaluate the susceptibility level of an individual DUT.
Features:
-
Burst module (IEC/EN 61000-4-4) up to 5.5kV
-
Surge module (IEC/EN 61000-4-5) up to 5kV
-
TSurge module (IEC/EN 61000-4-5); optional
-
PowerFail module (IEC/EN 61000-4-11)
-
Magnetic field tests with optional accessories
-
Built-in single phase coupler 300V/16A
-
Manual operation from front panel
Applications:
-
Industry
-
Medical
-
Residential
-
Telecom
-
Components
-
Broadcast
-
Renewable Energy
Specifications:
|
Interfaces |
|
Serial interface |
USB |
|
Parallel interface |
IEEE 488, addresses 1 - 30 |
|
Analog output |
0 - 10VDC to control an external transformer |
|
CN interface |
15pin SubD connector to control an external coupling network |
|
Fail inputs |
DUT monitoring via Fail1 and Fail2 input (one each) |
|
Dimensions |
|
Dimensions |
19", 3HU, 19", 6HU, (with TSurge5 module) |
|
Weight |
approx. 25kg |
|
Mains |
|
Supply voltage |
115V/230VAC +10%/-15% |
|
Power |
approx. 75W |
|
Frequency |
50/60Hz |
|
Fuses |
2 x T 2AT (230V) or 2 x T 4AT (115V) |
|
Safety |
|
Safety standard |
EN/IEC 61010 |
|
Security circuit |
Control input (24VDC) |
|
Warning lamp |
Floating contact (max. 230V/6A) |