Fluke TiR29 Diagnostic Thermal Imager
Features:
-
Superior image quality
-
One-handed, easy-to-use interface
-
Torture tested
-
Patented Fluke IR-Fusion
-
Interchangeable lenses
Specifications:
|
Temperature measurement range (not calibrated below -10 °C) |
-20 °C to +150 °C (-4 °F to +302 °F) |
|
Temperature measurement accuracy |
± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
|
On-screen emissivity correction |
Yes |
|
On-screen reflected background temperature compensation |
Yes |
|
On-screen transmission correction |
Yes |
|
Imaging performance |
|
Image capture frequency |
9 Hz refresh rate or 60 Hz refresh rate depending upon model variation |
|
Detector type |
Focal Plan Array, uncooled microbolometer, 280 x 210 pixels |
|
Thermal sensitivity (NETD) |
≤ 0.045 °C at 30 °C target temp. (45 mK) |
|
Total pixels |
58,800 |
|
Infrared spectral band |
7.5 μm to 14 μm (long wave |
|
Visual (visible light) camera |
Industrial performance 2.0 megapixel |
|
Minimum focus distance |
45 cm (approx. 18 in) |
|
Standard infrared lens type |
|
Field of view |
23 ° x 17 ° |
|
Spatial resolution (IFOV) |
1.43 mRad |
|
Minimum focus distance |
15 cm (approx. 6 in) |