The answer to manufacturers' demand for a mid-range, multi-capability EMC immunity tester, EMCPro® is easily configured to meet today's immunity standards required for CE Marking and compliance requirements. Operating via Thermo KeyTek's easy to use Windows®-based PC software or from the front panel, it enables test engineers and technicians to run compliance-level EMC immunity tests in accordance with European Norm requirements. Portable and low cost, the EMCPro® is ideal for companies who require flexibility, versatility, and the highest test level-to-cost ratio instrument on the market.
Configurations for the Keytek EMCPro:
|
Model PRO-SURGE |
|
Surge per IEC 61000-4-5. Will do part of UL1449 |
|
Voltage Waveform |
1.2/50µs |
|
Peak Voltage |
250V - 6.6kV ±5%, 12Ω Mode |
|
250V - 6.0kV ±5%, 2Ω mode |
|
Peak Current |
125 A - 3.3 kA ±10% |
|
Additional 10 ohm Resistor |
Software selectable |
|
Repetition Rate |
Up to 4 per minute |
|
Open-circuit Voltage |
Front time: |
1.2µs ±30% |
|
Duration: |
50µs ±20% |
|
Undershoot: |
≤30% |
|
Line sync accuracy |
±15%, 50 - 277 VAC |
|
Model PRO-EFT |
|
EFT per IEC 61000-4-4 and ANSI |
|
Voltage Waveform |
5/50 ns ±30% |
|
Peak Voltage |
250V - 4.4 kV ±5% |
|
Burst Period |
300 ms ±10% |
|
Burst Duration |
15 ms ±20% |
|
Frequency |
1 kHz - 100 kHz in 0.5 kHz steps, ±10% |
|
DC Blocking Capacitor |
10 nF (internal) |
|
Model PRO-RING* |
|
Surge Ring Wave per ANSI and UL. Will do part of 61000-4-12. |
|
Voltage Waveform |
100 kHz damped cosine |
|
Peak Voltage |
250 - 6.6kV ±5% |
|
Repetition Rate |
<4/minute at 6 kV, faster at lower voltages |
|
Open-circuit Voltage |
Rise Time: 0.5µs ±30% |
|
Short-circuit Current |
Vp/Ip: 12 ohm ±3 ohm or 30 ohm ±8 ohm software selectable |
|
*Pro-Telecom and Pro-Ring can not be installed together in the same unit |
|
Surge Waveform Monitoring |
|
Lines Monitored |
Monitors are automatically switched to match the generator coupling mode |
|
Open-circuit Voltage |
1000:1 ±10% |
|
Short-circuit Current Attenuation: |
200:1 ±7% |
|
Model PRO-HPOWER |
|
Power Frequency Magnetic Field per 61000-4-8 |
|
Field Frequency |
50Hz/60Hz |
|
Field Amplitude |
0.5-4A/m, in 0.25A steps, ±10% (with CM-HCOIL) up to 100A/m with the optional external HPOWER-EXT |
|
AC Source |
Internal |
|
Resolution |
0.25 Amp minimum |
|
Coil Factor |
0.65 to 1.00 |
|
Coil Resistance |
0.05Ω maximum |
|
Model PRO-HPULSE |
|
Pulse Magnetic Field per IEC 61000-4-9 |
|
Field Pulse |
8/20µs |
|
Field Amplitude |
100A/m -1000A/m, ±10% |
|
Resolution |
5A/m |
|
Coil Factor |
0.65 to 1.00 |
|
Model PRO-PQF |
|
Dips and Interrupts per IEC 61000-4-11 |
|
Dips |
70%, 40% |
|
Interrupts |
0% (short and open) |
|
Transition Time |
1µs - 5µs |
|
Inrush |
Minimum: |
250 Amps @ 100V - 120V |
|
Minimum: |
50 0Amps @ 220V - 240V |
|
AC Voltage |
50 VAC - 250 VAC, 50 Hz - 60 Hz |
|
AC Current |
16A Max |
|
PQF Sync Output |
5V signal occurs at each Dip or interrupt transition |
|
Dip Duration |
10 msec min at 60 Hz |
|
2 msec min at 50 Hz |
|
PQF Waveform Monitoring |
|
Voltage Input Connection |
Fixed, L1 to L2 |
|
Voltage Attenuation |
100:1 ±5% |
|
Current Input Connection |
Fixed, L1 |
|
Peak Current |
Minimum 500A inrush into 1700µF |
|
Current Attenuation |
200:1 ±5% |
|
Model PRO-BASE |
|
System Voltage |
90 VAC - 240 VAC, 50 Hz - 60 Hz |
|
Integrated EUT Mains Coupler/Decoupler |
AC Voltage: |
1 phase, 50-250VAC, 50/60Hz |
|
AC Current: |
16A max |
|
DC Voltage: |
100 VDC max |
|
DC Current: |
10A max |
|
Frequency: |
50/60Hz |
|
EUT Connectors: |
Nema, British, Schuko |
|
Control Interface: |
RS232 Fiber-optic |
|
Safety Features: |
External Interlock for users
Interlock for CCL connector
External stop input |