The 1750 Series Waveform/Vector Monitors are comprehensive signal monitors that also provide extended measurement capability. These signal monitors can be retrofit into existing systems that use 1/2 rack width, 5 1/4 inch waveform or vector monitors.
The 1750 Series combines conventional monitoring capabilities with the ability to perform SCH phasing tasks that until now have required additional instrumentation. SCH phase and color frame matching can be measured directly by using the SCH mode. This capability makes the 1750 Series ideally suited to production and editing applications where the maintenance of SCH phase and color frame relationship is critical.
Features:
-
Dual Filter/Simultaneous Display
-
Two Instruments in One
-
SCH Phase and Color Framing
-
R-Y (V-Axis) Mode
-
RGB/YRGB Mode
-
Remote Control Capability
-
Line and field selection for VITS / ITS monitoring
-
Comprehensive signal monitoring
Specifications:
|
Waveform Mode (Vertical Deflection System) |
|
Deflection Factor |
1V input for 140 IRE display |
|
Gain Ranges |
Input signals between 0.7 V and 2 V can be adjusted to 140 IRE |
|
Frequency Response |
Flat: |
±2% from 50 kHz to 6 MHz |
|
IRE: |
Conforms to IEEE Standard 205 |
|
CHROMA: |
Response at 3.58 MHz does not vary between FLAT and CHROMA by more than 1% |
|
Pix Mon Output |
Frequency Response: |
50 kHz to 6 MHz |
|
Output Impedance: |
75Ω |
|
Calibrator Signal |
Frequency: |
100 kHz |
|
Amplitude: |
1 V |
|
Waveform mode (Horizontal Deflection System) |
|
Sweep |
Sweep will occur in all Horizontal mode settings with or without synchronization |
|
1FLD sweep repetition rate |
|
2FLD sweep repetition rate |
|
1H sweep repetition rate |
|
2H sweep repetition rate |
|
Vector Mode |
|
Chrominance Bandwidth |
Upper: |
-3 dB Point Fsc +500 kHz, ±100 kHz |
|
Lower: |
-3 dB Point Fsc -500 kHz, ±100 kHz |