Description: |
Compact ESD simulator with microprocessor based, large touch- |
|
|
sensitive LCD panel, built-in HV relay for contact-discharge, mains |
|
|
operation |
|
Basics: |
Discharge pistol, high voltage base unit, mains power supply |
|
|
adapter, (100 to 250 VAC), discharge network 150 pF/330 Ù, air- |
|
|
and contact-discharge tips, grounding cable, user manual |
|
Pulse data: |
Standard: Conforms to IEC/EN 61000-4-2 (2001) |
|
|
Special: Interchangeable networks for other standards |
|
Pulse networks: |
Network 150 pF/330 Ù as per IEC/EN 61000-4-2 (included) |
|
|
Optional ISO 10605 networks 150 pF/2 kÙ and 330 pF/2 kÙ |
|
|
Range of RC-networks for other standards: |
|
|
R = 0 Ù to 20 kÙ |
|
|
C = 50 pF to 2000 pF |
|
Discharge: |
Air-discharge: 200 V to 30 kV (in 100 V steps) |
|
|
Contact-discharge: 200 V to 30 kV (in 100 V steps) |
|
Discharge tips: |
Ball and point as per IEC and specials; exchangeable by threaded |
|
|
cap |
|
Charging voltage measurement: |
kV, accuracy better than ± 5% (stabilized) |
|
Discharge detection: |
Air-discharge only: indicated by the kV symbol being displayed in |
|
|
inverse, also acoustically in the single‘s operating mode. |
|
|
Threshold level on/off. |
|
Holding time: |
> 5 s (charging voltage ±5%) |
|
Charge resistor: |
50 MÙ |
|
Triggering: |
Trigger button in hand-grip |
|
Operation: |
Via touch panel and microprocessor |
|
Discharge modes: |
Air-discharge/contact-discharge |
|
Polarity: |
Positive, negative/automatic change |
|
Operating modes: |
Single/repetitive; Pulse counter 0 to 9999; |
|
|
Pre-select counter 0 to 9999; |
|
|
Repetition: |
|
|
- 0.5/1/5/10/20 or 25 Hz (air) |
|
|
- 0.5/1/5/10 or 20 Hz (contact) |
|
|
#NAME? |
|
Auto-shut-off: |
After 15 minutes idle time (without loss of the test parameters) |
|
Display: |
LCD panel showing: charging voltage, breakdown event, polarity, |
|
|
air-/contact-discharge, counter/preselect counter content |
|
Weight: |
Discharge pistol (w/o cable): 1.2 kg (2.6 lbs) approx. |
|
|
Base unit: 5.7 kg (12.6 lbs) approx. |
|
Ambient conditions: |
Operation: |
|
|
+5 to +40°C |
|
|
20 to 80% r.h. (non-condensing) |
|
|
68 to 106 kPa |