Teseq CT 419-5 Current Transformer for IEC / EN 61000-4-19

Rent Teseq CT 419-5 Current Transformer for IEC / EN 61000-4-19
Request Quote Print Page
Datasheet
IEC / EN 61000-4-19 specifies the differential current test in the frequency range 2 kHz to 150 kHz. Teseq offers with CT 419-5 a transformer with integrated matching network for testing EUTs like electricity meters. The CT 419-5 is fully compliant with the requirements of the standard and provides a simple and reliable method of injecting differential mode current into the equipment under test (EUT).


Teseq CT 419-5 Features:

 
  • Coupling transformer designed for IEC/EN 61000-4-19
  • Frequency range 2 kHz to 150 kHz
  • 4 mm banana sockets
  • 100 mΩ shunt


Teseq CT 419-5 Specifications:

 
Frequency range: 2 kHz to 150 kHz
Current max: 5 A
RF voltage: <22 V
Impedance: 1 Ω ±0.3 Ω
Shunt: 100 mΩ ±1 mΩ
Connections: 4 mm banana