Frequency range |
300 kHz to 3 GHz |
Maximum input level |
+40 dBm (10 W, MAIN connector), +20 dBm (100 mW, AUX connector) |
Input/output connector |
MAIN I/O connector |
|
Impedance: |
50 ½, N-type |
VSWR: |
≤1.2 (≤2.2 GHz), ≤1.3 (>2.2 GHz) |
AUX input/output connector: |
TNC-type |
Reference oscillator |
Frequency: |
10 MHz |
Starting characteristics: |
≤ 5 5 10-8/day (after 10 minutes of warm-up, referred to frequency after 24 hours warm-up) |
Aging rate: |
≤ 2 5 10-8/day, ≤ 1 5 10–7/year (referred to frequency after 24 hours warm-up) |
Temperature characteristics: |
≤ 5 5 10–8 (0° to 50°C, referred to frequency at 25°C) |
External standard input: |
10 MHz or 13 MHz (±1 ppm), input level: 2 to 5 Vp-p |
Power meter |
Frequency range: |
300 kHz to 3 GHz |
Level range: |
0 to +40 dBm, –10 to +40 dBm (CDMA measurement) |
Level accuracy: |
±10% (0 to +40 dBm, after zero-point calibration), ±10% (–10 to +40 dBm, 18° to 28°C, at average value, after zero-point calibration) |
Signal generator |
Frequency |
Range: |
300 kHz to 3 GHz |
Resolution: |
1 Hz |
Accuracy: |
Reference frequency accuracy ±100 mHz |
Output level |
Level range (no modulation or analog modulation): |
–13 to –133 dBm (Main), +7 to –133 dBm (AUX) |
Level accuracy: |
±1 dB (10 MHz to 2.2 GHz, ≥–123 dBm, 18° to 28°C), ±3 dB (10 MHz to 2.2 GHz, ≥–133 dBm),
±2 dB (>2.2 GHz, ≥–123 dBm, 18° to 28°C), ±4 dB (>2.2 GHz, level: ≥–133 dBm) |
Radiated interference: |
1 μV/50 Ω (carrier frequency measured, 25 mm from front panel with two-turn 25 mm diameter loop antenna) |
Signal purity |
Spurious: |
≤–50 dBc (at CW, offset frequency 100 kHz to ≤50 MHz; where carrier frequency: other than 1300 to 1400 MHz and 2000 to 2100 MHz), ≤–40 dBc (for all band) |
Harmonics: |
≤–25 dBc (at CW) |