Anritsu MW8208A 850 MHz PIM Tester for Verizon

Rent Anritsu MW8208A 850 MHz PIM Tester for Verizon
Enlarge Image
Anritsu MW8208A
Request Quote Print Page

The Anritsu MW8208A 850 MHz PIM Tester for Verizon is an integrated source and receiver that generates a high-power signal that excites micro arching and PIM. These signals are picked up by the on-board receiver.
 
Measurements:

 

  • PIM
  • Noise Floor
  • Distance-to-PIM (DTP
 
Anritsu MW8208A Features
  • Patented Distance-to-PIM (DTP). The Fastest Way to Pinpoint the Source of PIM
  • 2 x 40 Watts of RF Power. Finds PIM that cannot be found by 2 x 20 Watt PIM testers
  • Tx Band: 869 to 894 MHz
  • IMD Band: 824 to 849 MHz
  • IMD Orders: 3rd, 5th, or 7th orders (user selectable)
  • Power Levels: 20W, 30W, 40W
Anritsu MW8208A Specs
Measurements
PIM 3rd, 5th, and 7th order intermodulation product in receive band (user selectable)
Noise Floor Rx noise floor of base station
Distance-to-PIM Distance and magnitude of multiple PIM sources
PIM Measurement Ranges
RF Test Power Two CW tones of 20, 30, or 40 Watts (≈ 43, 45, 46 dBm) (user selectable)
Transmit Frequency Range 869 to 894 MHz
3rd, 5th, and 7th Order Frequency Ranges 880 to 915 MHz
Residual PIM Performance < -112 dBm/-155 dBc typical
Measurable PIM order 3rd, 5th, and 7th order intermodulation product (if in band)
Distance-to-PIM Distance and magnitude of multiple PIM sources
PIM Master Connectors
Test Port 7/16 DIN, female, 50 Ω
RF Out Type N, female, 50 Ω (connect to RF In on instrument)
10 MHz Out BNC, female, 50 Ω, 10 MHz (connect to Ext. Ref. In on instrument)
USB Interface Type B (connect to USB Type A port on instrument)
AC Power IEC60320 C14
Power
Emergency Stop Red push button
AC Power 90-240 VAC, 50/60 Hz
Electromagnetic Compatibility
European Union CE Mark, EMC Directive 2004/108/EC
Australia and New Zealand C-tick N274
Interference EN 61326-1:2006
Emissions EN 55011:2007
Immunity EN 61000-4-2/-3/-4-4/-4-5/-4-6/-4-11
Safety
Safety Class 2006/95/EC, EN 61010-1 Class 1
Product Safety IEC 60950-1 when used with Company supplied Power cable
Environmental
Operating Temperature -10 °C to 55 °C
Maximum Humidity 95%
Shock MIL-PRF-28800F Class 2
Storage -51 °C to 71 °C
Altitude 4600 meters, operating and non-operating
Size & Weight 300 mm x 425 mm x 500 mm (12 in x 17 in x 20 in)
Weight 27 kg (59 lbs)