The Wiltron/Anritsu Site Master S113B Network Analyzer is the instrument of choice for transmission line/antenna installation and maintenance. It is the best way to reduce maintenance expenses and improve quality. It replaces stacks of heavy, expensive and complex test equipment. The Site Master's frequency domain reflectometry technique allows it to find problems before they become catastrophic faults, thereby creating huge cost savings.
Anritsu SiteMaster S113B Specs
Frequency range |
5 to 1200 MHz |
Frequency accuracy (CW mode) |
75 ppm |
Frequency resolution |
10 kHz |
Display data points |
Selectable: 130,259,517 |
Immunity to interfering RF signals |
up to +10 dBm |
Return loss |
Range: 0 to 54 dB; |
Resolution: 0.01 dB |
SWR |
Range: 1 to 65 |
Resolution: 0.01 |
Cable loss |
Range: 0 to 20 dB |
Resolution: 0.01 dB |
Distance-to-fault |
Vertical range Return loss: 0 to 54 dB |
SWR: 1 to 65 |
Horizontal range (meter): 0 to (dp x resolution), |
where dp = 128, 256 or 512 |
Horizontal resolution, rectangular windowing resolution (meter):(1 .5 x 108)(Vp)/delta frequency |
Wattmeter |
Display range: -80 to +80 dBm, |
(RF power monitor, Option 5) |
10 pW to 100 kW |
Detector range: -50 to +20 dBm, 10 mW to 100 mW |
Offset range: 0 to +60 dB |
Resolution: 0.1 dB |
Trace memory |
Up to 200 |
Instrument configuration |
10 |
Test port connector |
Precision N female |
Maximum input |
RF OUT test port: +22 dBm |
RF IN test port: +10 dBm |
RF power detector: +20 dBm,50 ohms |
RF IN Spectrum Analyzer port :
+20 dBm safe input, +27 dBm damage level |
Temperature |
Operating: 0°C to +50 °C |
Storage: -20 °C to +75 °C |