Anritsu S362E Site Master Cable & Antenna Analyzer

Anritsu S362E Site Master Cable & Antenna Analyzer
Enlarge Image
Anritsu Site Master S362E
Request Quote Print Page
Manual Brochure
The S362E characterizes cable and antenna systems with return loss, cable loss, VSWR, distance-to-fault measurements. Also includes 1-port phase and Smith chart displays. Offers faster than 1 ms/data point sweep speed and a dual display.
 
Anritsu Site Master S362E Features
  • Cable & Antenna Analyzer: 2 MHz to 6 GHz
  • Spectrum Analyzer: Spectrum Analyzer
  • Return loss, VSWR, cable loss, DTF
  • 2-port transmission measurements with 32V bias tee
  • 1-port phase, Smith chart
  • Optical DTF measurements
  • PIM 3 rd, 5th and 7th Order Frequency measurements
  • Dual display mode capabilities
  • Built-in, editable signal standard and cable standard lists
  • Trace overlay and trace math to monitor changes with - Reference traces
  • Marker table with automatic peak/valley markers
  • GPS tagging
  • Limit lines and alarming for providing reference standards
  • GPS tagging of data to verify location of tests
  • Master Software Tools for post-analysis and report generation
Anritsu Site Master S362E Specs
Spectral Purity
SSB Phase Noise @ 1 GHz –100 dBc/Hz, –110 dBc/Hz typical @ 10 kHz offset
–105 dBc/Hz, –112 dBc/Hz typical @ 100 kHz offset
–115 dBc/Hz, –121 dBc/Hz typical @ 1 MHz offset
Amplitude Ranges
Dynamic Range > 95 dB (2.4 GHz), 2/3 (TOI-DANL) in 10 Hz RBW
Measurement Range DANL to +26 dBm
Display Range 1 to 15 dB/div in 1 dB steps, ten divisions displayed
Reference Level Range –120 dBm to +30 dBm
Attenuator Range 0 to 55 dB, 5.0 dB steps
Maximum Continuous Input +35 dBm
Amplitude Units Log Scale Modes: dBm, dBV, dBmv, dBμV
Linear Scale Modes: nV, μV, mV, V, kV, nW, μW, mW, W, kW
Amplitude Accuracy
100 kHz to 4.0 GHz ± 1.25 dB, ± 0.5 dB typical
> 4.0 GHz to 6 GHz ± 1.50 dB, ± 0.5 dB typical