EMI / TDK-Lambda TCR20T500-4 Three Phase DC Power Supply

STANDARD AC INPUT
Standard AC input is 208/220/230 volts, 3 O 47 to 63Hz. The supply will function within full specification from 190 to 253 volts. Phase-to-phase voltage balance requirements ± 2% to achieve ripple specification. Larger deviations can be accommodated by recalibrating supply at installation. Phase rotation sequence of AC input is not required. Current draw per phase: 2.5KW units 12 amps 5KW units 23 amps, 10KW units 46 amps at full load.