Fischer Custom Communications F-120-9A Bulk RF Current Injector Probe/Clamp

Fischer Custom Comm. F-120-9A Bulk RF Current Injector Probe/Clamp
Enlarge Image
Request Quote Print Page
Datasheet

 

Features:

  • 7 dB attenuation between 100 kHz and 230 MHz when measured into a 50 ohms fixture
  • Perform IEC 1000-4-6 testing with 20 watts or less of RF power
  • Usable up to 200 watts
  • Accommodates EUT cables up to 40 mm in diameter

 

Specifications:

Frequency 10 kHz - 2 30 MHz
Internal Diameter 40 mm (1.58 inches)
External Diameter 127 mm (5 inches)
Thickness 134 mm (5.28 inches)
Input Power 100 wattss for 30 minutes or 200 watts for 15 minutes
Connector Type N