FLIR Systems T250 Infrared Camera

FLIR Systems T250 Infrared Camera
Enlarge Image
FLIR Systems T250 Infrared Camera FLIR Systems T250 Infrared Camera
FLIR Systems T250
Request Quote Print Page
Manual Datasheet

FLIR's new T250 infrared camera expands the choices available to thermographers and maintenance professionals who need to avoid costly downtime of electrical systems and equipment.
 

Picture-in-Picture and much more
 

With the exclusive FLIR Picture-in-Picture capability, you combine infrared and visible light detail to easily show hidden trouble. Speed through reporting of trouble spots with the help of FLIR's QuickReport software. QuickReport includes easy image organization tools and report templates so you can concentrate more on your IR inspection.

 
FLIR Systems T250 Features
  • High Quality 200 x 150 IR Resolution
  • Thermal sensitivity of 80 mK (NETD)
  • Integral 1280 x 1024 visible light camera
  • Video lamp for quality visible images
  • Interchangeable lens for greater versatility
  • Picture in Picture to show fusion images
  • Touch screen text, image marker, sketch, voice
  • 3.5 inch touch-screen LCD
  • Small and lightweight
  • Picture-in-Picture (scalable)
  • Laser pointer
  • MeterLink
  • Copy to USB
  • 3.1 Mp digital camera with built-in LED lights
  • Touch screen & Thumbnail gallery
  • Voice annotations via Bluetooth™
  • Sketch/image markers (FLIR T250)
  • Radiometric IR video streaming
  • Panorama support (FLIR T250)
  • Dewpoint and insulation alarm (FLIR B250/B335)
FLIR Systems T250 Specs
Field of View (FOV) / Close Focus Limit 25° x 19° / 0.4 m (1.31 ft.)
Thermal sensitivity (NETD) 0.08°C @ +30° (+86°F) / 80mK
Detector Type Focal Plane Arrany (FPA) microbolometer
IR resolution 200 x 150
Spectral range 7.5 to 13 μm
Digital zoom and pan/focus 1x - 2x continuous/auto & manual focus
IFOV (with 25° lens) 2.18 mRad
Voltage 11-16 VDC
AC operation AC adapter, 90-260 VAC input. 12 V output to camera
Battery type Rechargeable Lithium-Ion battery
Rechargeable Lithium-Ion battery 4 hours+
Operating temperature range -15°C to +50°C (5°F to 122°F)
Storage temperature range -40°C to +70°C (-40°F to +158°F)
Humidity 95% relative humidity +25°C to +40°C (+77°F to +104°F) non condensing