Graphtec GL820 midi Logger

Graphtec GL820 midi Logger
Request Quote Print Page
Brochure
Number of analog input channels 20 ch, Expandable up to 200 ch by unit of 20 ch External input output Input *1 Trigger or Sampling input 1ch, Logic or Pulse input 4 ch Output *1 Alarm output 4 ch Sampling interval 10 ms to 1 h (in 10 ms to 50 ms, voltage only and limited channel), External Time scale 1 sec to 24 hour/division Trigger function Action Start or stop capturing data by the trigger Source Start: Off, Input signal, Alarm, External *1, Clock, Week or Time Stop: Off, Input signal, Alarm, External *1, Clock, Week or Time Combination OR or AND condition at the level of signal or edge of signal Condition Analog: Rising, Falling, Window-in, Window-out Pulse: Rising, Falling, Window-in, Window-out Logic: Rising, Falling Alarm function Detecting method Level or edge of signal Condition Analog: Rising, Falling, Window-in, Window-out Pulse: Rising, Falling, Window-in, Window-out Logic: Rising, Falling Alarm output *1 4 channels, Output type: Open collector (pulled-up to 5 V by resistor 10 kΩ) Pulse input function *1 Accumulating count mode Accumulating the number of pulses from the start of measurement
Range: 50, 500, 5k, 50k, 500k, 5M, 50M, 500M counts/F.S. Instant count mode Counting the number of pulses per sampling interval
Range: 50, 500, 5k, 50k, 500k, 5M, 50M, 500M counts/F.S. Rotation count (RPM) mode Counting the number of pulses per second and then it is converted to RPM
Range: 50, 500, 5k, 50k, 500k, 5M, 50M, 500M rpm /F.S. Max. input pulse rate 50k pulses/sec or 50k counts per sampling interval (16 bits counter is used) Calculation function Between channels Addition, Subtraction, Multiplication and Division for analog input Statistical Select two calculations from Average, Peak, Max., Min., RMS Search function Search for analog signal levels, values of logic or pulse or alarm point in captured data Interface to PC Ethernet (10 BASE-T/100 BASE-TX), USB (Full speed) Storage device Built-in Flash memory (2 giga-bytes), USB memory device *2 Data saving function Captured data Direct saving of data into built-in Flash memory or USB memory device Others Setting conditions, Screen copy Ring capturing mode Function: ON/OFF, Number of capturing point: 1000 to 2000000 (size of the capture data will be limited to 1/3 of available memory when in Ring Mode) USB memory device emulation USB Memory emulation mode (Transfer or delete the file in built-in memory) Engineering scale function Set based on the reference point of the scaled output and input signal for each channel (Voltage measurement: four points are necessary to scale the output, Temperature measurement: two points are necessary to scale the output). Display Size 5.7 inch TFT color LCD (VGA: 640 x 480 dots) Formats Waveform + Digital, Waveform only, Calculation + Digital, Expanded digital Operating environment 0 °C to 45°C, 5 % to 85 % RH
(When operating with battery pack 0 °C to 40 °C, charging battery 15 °C to 35°C) Power source AC adapter (100 V to 240 V, 50/60 Hz)
DC power (8.5 V to 24 V DC, max. 26.4 V)*3, Battery pack*3 Power consumption 32VA or lower
(When operating with AC adapter, displaying LCD, charging battery pack) External dimensions (WxDxH) approx. 232 x 152 x 50 mm Weight approx. 900 g (Excluding AC adapter and battery pack)
*1 Logic alarm cable (B-513) option is required. Input signal of External sampling, Logic, Pulse; Maximum voltage: 24 V, Threshold: approx. 2.5 V, Hysteresis: approx. 0.5 V
*2 Size of the USB memory device is unlimited. Maximum file size is limited to 2 GB
*3 DC drive cable (B-514) or battery pack (B-517) option is required.


Applications:

  • Car & Transportation Equipment
  • Home Appliance Industry
  • Electronic / Mechanical Industry
  • Production Line, Service & Maintenance etc
" />

Features:

  • Modular system allows expansion up to 200 channels
  • All channels are isolated, each with multifunction input
  • Huge built-in 2GB Flash memory
  • Large easy-to-read 5.7-inch TFT colour LCD
  • PC -friendly, supports USB memory stick, has USB and LAN ports
  • Easy application software

Specifications:

Number of analog input channels 20 ch, Expandable up to 200 ch by unit of 20 ch
External input output Input *1 Trigger or Sampling input 1ch, Logic or Pulse input 4 ch
Output *1 Alarm output 4 ch
Sampling interval 10 ms to 1 h (in 10 ms to 50 ms, voltage only and limited channel), External
Time scale 1 sec to 24 hour/division
Trigger function Action Start or stop capturing data by the trigger
Source Start: Off, Input signal, Alarm, External *1, Clock, Week or Time
Stop: Off, Input signal, Alarm, External *1, Clock, Week or Time
Combination OR or AND condition at the level of signal or edge of signal
Condition Analog: Rising, Falling, Window-in, Window-out
Pulse: Rising, Falling, Window-in, Window-out
Logic: Rising, Falling
Alarm function Detecting method Level or edge of signal
Condition Analog: Rising, Falling, Window-in, Window-out
Pulse: Rising, Falling, Window-in, Window-out
Logic: Rising, Falling
Alarm output *1 4 channels, Output type: Open collector (pulled-up to 5 V by resistor 10 kΩ)
Pulse input function *1 Accumulating count mode Accumulating the number of pulses from the start of measurement
Range: 50, 500, 5k, 50k, 500k, 5M, 50M, 500M counts/F.S.
Instant count mode Counting the number of pulses per sampling interval
Range: 50, 500, 5k, 50k, 500k, 5M, 50M, 500M counts/F.S.
Rotation count (RPM) mode Counting the number of pulses per second and then it is converted to RPM
Range: 50, 500, 5k, 50k, 500k, 5M, 50M, 500M rpm /F.S.
Max. input pulse rate 50k pulses/sec or 50k counts per sampling interval (16 bits counter is used)
Calculation function Between channels Addition, Subtraction, Multiplication and Division for analog input
Statistical Select two calculations from Average, Peak, Max., Min., RMS
Search function Search for analog signal levels, values of logic or pulse or alarm point in captured data
Interface to PC Ethernet (10 BASE-T/100 BASE-TX), USB (Full speed)
Storage device Built-in Flash memory (2 giga-bytes), USB memory device *2
Data saving function Captured data Direct saving of data into built-in Flash memory or USB memory device
Others Setting conditions, Screen copy
Ring capturing mode Function: ON/OFF, Number of capturing point: 1000 to 2000000 (size of the capture data will be limited to 1/3 of available memory when in Ring Mode)
USB memory device emulation USB Memory emulation mode (Transfer or delete the file in built-in memory)
Engineering scale function Set based on the reference point of the scaled output and input signal for each channel (Voltage measurement: four points are necessary to scale the output, Temperature measurement: two points are necessary to scale the output).
Display Size 5.7 inch TFT color LCD (VGA: 640 x 480 dots)
Formats Waveform + Digital, Waveform only, Calculation + Digital, Expanded digital
Operating environment 0 °C to 45°C, 5 % to 85 % RH
(When operating with battery pack 0 °C to 40 °C, charging battery 15 °C to 35°C)
Power source AC adapter (100 V to 240 V, 50/60 Hz)
DC power (8.5 V to 24 V DC, max. 26.4 V)*3, Battery pack*3
Power consumption 32VA or lower
(When operating with AC adapter, displaying LCD, charging battery pack)
External dimensions (WxDxH) approx. 232 x 152 x 50 mm
Weight approx. 900 g (Excluding AC adapter and battery pack)
*1 Logic alarm cable (B-513) option is required. Input signal of External sampling, Logic, Pulse; Maximum voltage: 24 V, Threshold: approx. 2.5 V, Hysteresis: approx. 0.5 V
*2 Size of the USB memory device is unlimited. Maximum file size is limited to 2 GB
*3 DC drive cable (B-514) or battery pack (B-517) option is required.


Applications:

  • Car & Transportation Equipment
  • Home Appliance Industry
  • Electronic / Mechanical Industry
  • Production Line, Service & Maintenance etc