The Hioki 3197 Power Quality Analyzer is a compact, easy-to-operate, and affordable power quality measurement instrument. It has streamlined the functions of Power Quality Analyzer 3196, one of the power quality measurement instruments recognized as a standard worldwide. While the basic power anomaly measurement capabilities are retained, the smaller size and simpler measurement operations ensure that anyone can handle it easily. Also, in response to the recently growing interest in power management and energy saving measures, power measurement functions have been enhanced and display screen capabilities have been added for time series graphs of voltage, current and power, as well as energy consumption and demand graph displays. These features are ideally suited to the particular measurements required when a power anomaly occurs, and for applications involving power management and energy saving measures.
Hioki 3197 Features
- Monitor For:
- Inrush Current
- Voltage Swells
- Voltage Dips
- Transient Overvoltage
- Interruptions
- Measure and Record:
- Power and Power Factor
- Active/Reactive Energy
- Demand
- Load Changes (with graph display!)
- Voltage and Current
Hioki 3197 Specs
Measurement lines |
Single-phase/two-wires, Single-phase/three-wires, Three-phase/three-wires, Three-phase/four-wires |
Measurement line frequency |
Auto-detect (50Hz/60Hz) |
Voltage range |
600.0V AC |
Current ranges |
Manually switch-able from 2 range sets according to Clamp sensor 500.0mA / 5.000A/ 50.00A / 10.00A / 100.0A / 500.0A / 1.000kA / 5.000 kA |
Measurement items |
Impulsive voltage quality: |
Transient overvoltage (Impulse) |
RMS voltage quality: |
Voltage swell, Voltage dips, Voltage interruption |
Power quality: |
Frequency, Voltage, Current, Current peak, Active/Reactive/Apparent power, Power factor (displaced power factor) |
Three phase quality: |
Voltage unbalance ratio, Current unbalance ratio |
Harmonic quality (Up to 50th order): |
Harmonic voltage, Harmonic current, Harmonic power, Harmonic voltage/current phase angle, Total harmonic voltage distortion, Total harmonic current distortion (THD-F, THD-R) |
Interval settings: |
AUTO / 1 / 5 / 10 / 15 / 30 / 60 minutes |
Maximum record-able period |
125 Days with internal non-volatile memory of 4 MB-stored data will not be deleted upon power OFF; partition memory into 4 segments for maximum 31 days of recording each |
Internal memory |
4 MB |
PC Interface |
USB Ver.2.0 |
Power supply |
9418-15 AC ADAPTER or 9459 BATTERY PACK |
Dimensions, mass |
128W × 246 H × 63 D mm, 1.2 kg with battery pack |