Infratek 106A Power Analyzer

Infratek 106A Power Analyzer
Enlarge Image
Infratek 106A
Request Quote Print Page
Datasheet
The Infratek 106A high precision broadband Power Analyzer has a wide current range 1mA-40A designed to offer the engineer the ability to measure low stand by power, power at low power factor of an idling transformer, or power of a frequency inverter driving a large motor.

The Infratek 106A high performance Power Analyzers are available as single- and three phase instruments. The 106A is designed to cope with the extreme signals generated on frequency inverter drivers and other electronically generated signals. You don't have to worry about the signal waveforms. The analyzers will always provide precise and reliable measurements.The large and very bright monitor lets you read the display values from a distance of up to 4m.

Options:
Option 01 RS-232 Interface and Centronics printer output incl. Windows Operating Software to control, read and store data
Option 02 RS-232 and IEEE-488 Interface, Centronics printer output incl. Windows Operating Software to control, read, and store data printer output
Option 03 RS-232 and IEEE-488 Interface, Centronics printer output, and 4 programmable analog outputs, 8 analog inputs incl. Windows Operating Software to control, read, and store data, read analog inputs
Option 04 3-Phase current sensor module 0-100A (supply by 106A)
Option 04a 3-Phase current sensor module 0-200A (supply by 106A)
Option 06 106A driver for Nat. Instrument LabView
Option 07/M Software for Motor Testing
Option 07/T Software for Transformer Testing
Option 08 TTl-input for external synchronization
Option 09 Network to form artificial neutral
(mainly frequency inverter measurements)
Option 10 0-300A, 0-3000A flexiable current clamps with connector to clamp input of Power Analyzer (1 per phase). 1% 50/60Hz


Features:

  • Suitable for frequency inverter drivers
  • Large, bright display for 10 or 40 values
  • DC-1MHz, 1.5mA-40A, 0.3V-1000V
  • 0.1% and 0.05% accuracy
  • Scope function, Bar charts, Harmonics 1-99
  • IEEE-488, RS232, Analog outputs / inputs
  • Windows Operating Software
 

Specifications:

Voltage 8 ranges: 0.3 V, 1 V, 3 V, 10 V,
30 V, 100 V, 300 V, 1000 V
 
Frequency range DC, 0.1 Hz-1 MHz
Crest Factor 3:1 at 50 % full scale (fs)
Input Impedance 1 MOhm
Common Mode 50 Hz/100 kHz 160 dB/100 dB
Standard accuracy 23°C;
rms, mean, rectified mean; 0.3V typical
1 Hz-1 kHz ±(0.1 % rdg +0.1 % range)
DC, 1 kHz-10 kHz ±(0.2 % rdg +0.2 % range)
10 kHz-100 kHz
±(0.3 %1 range + 0.04 % /kHz rdg)
100 kHz-300 kHz
±(0.3 %/ range + 0.04 % /kHz rdg), typical
Improved accuracy
±(0.05 % rdg + 0.07 % range)
Current 13 ranges: 1.5 mA, 5 mA, 15 mA, 50 mA, 150 mA, 500 mA. 1.5 A, 5 A; 1, 3, 10, 30, 100 A. Max. 1 A, 5 A, 30 A, resp.
Frequency range DC, 0.1 Hz-300 kHz / 1 MHz
Crest Factor 3:1 at 50 % full scale (fs)
Common Mode 50 Hz/100 kHz 160 dB/120 dB
Standard accuracy 23°C; 1 A-, 5 A-, shunt input 30 A input
1 Hz-1 kHz ±(0.1%rdg +0.1 % rng)
±(0.1%rdg+0.1 % rng)
DC, 1 kHz-10 kHz ±(0.2 % rdg + 0.2 % rng)
±(0.7 % rdg + 0.2 % rng)
10 kHz-100 kHz #0.3 % range+ 0.04 %/kHz rdg) ±(0.3 % rng + 0.5 %/kHz rdg), typical
100 kHz-300 kHz ±(0.3 % range + 0.04 %/kHz rdg), typical
Lowest ranges 1.5 mA, 15 mA,
1 A: typical.
Improved accuracy
1 Hz-400 Hz
±(0.05 % rdg + 0.07 % range)
Power 104 ranges corresoondino to the products V x A.  
Frequency range DC, 0.1 Hz-300 kHz
45 Hz-65 Hz (0.1 % rdg + 0.01 % range)
1 Hz-1 kHz Add accuracy percentage figures of current and voltage,
DC, 1 kHz-10 kHz +0.04 %/kHz PF
10 kHz-100 kHz
PF= 0 to ±0.1
PF= 0 to ±1
PF= 0 to ±1
PF=1