Kaelus IQA-901C PIM Analyzer


Need Help? Call (800) 404-2832ATEC AssuranceWorldwide Delivery
Kaelus IQA-901C PIM Test Set
Enlarge Image
Kaelus (Summitek) IQA-901C
Request Quote Print Page
IQA-901C Datasheet
The Kaelus IQA-901C PIM Analyzer operates at a transmission and receiving band frequency range of approximately 900MHz and possesses RTF-1000A capability. The IQA Passive Intermodulation (PIM) analyzer is a feature-rich, high power PIM test solution which fulfills the IEC 62037 standard for passive intermodulation, its innovative design increasing safety and efficiency. This field-proven analyzer enables network operators to improve site performance by finding and eliminating sources of passive intermodulation at the cell site. The design includes an integrated panel PC with intuitive touch screen interface for performing tests and generating site reports. The Kaelus IQA-901C PIM Analyzer performs immediate and accurate Distance-to-PIM tests, informing you of the distance and magnitude of all PM sources simultaneously, both within the antenna system and beyond the antenna itself. With the growing amount of systems which utilize duplex transmissions paired with collocated transmitters and receivers, the Kaelus IQA-901C PIM Test Set is an essential tool to discover distortions to RF transmissions.
 
The Kaelus IQA-901C PIM Analyzer is the ninth model in the Kaelus IQA PIM Analyzer Series.
 
Kaelus (Summitek) IQA-901C Features
  • Rugged, reliable construction suitable for field use
  • Integrated polycarbonate transit case
  • Range to Fault (RTF) enabled
  • Fully configurable frequencies, powers and IM products
  • Simple to operate touch screen interface
  • Spectrum monitor, frequency sweep and time trace modes
Kaelus (Summitek) IQA-901C Specs
Frequency Ranges
TX RANGE 925-960 MHz
RX RANGE (PIM) 880-915 MHz
System
Measurement method Reverse (reflected) PIM, 3rd, 5th, 7th and 9th order
Residual PIM < -115dBm/-158dBc max (<-125dBm/-168dBc typ.)
User interface ports 2x USB, x1 LAN 1x RF output (7-16 DIN female)
Display 8.4in (213mm) touch screen display
Transmitter
Frequency increment 50 kHz
Frequency accuracy ± 5ppm (max), aging ± 1ppm (max) after first year
Power per tone (adjustable) 2x 2 to 20W (+33 to +43dBm)
Power accuracy (per tone) ± 0.5dB (max)
Receiver
Measurement noise floor < -128dBm
Measurement range -50dBm to -128dBm
Electrical
Mains power 115-230V, 50/60Hz AC
Power consumption 650W
Mechanical
Dimensions 19 x 18 x 12in (500 x 457 x 305mm)
Weight < 50lbs (22.7kg)
Cooling Forced air
Environmental
Operating temperature range -10°C to +40°C
Storage temperature range -20°C to +60°C
Ingress protection (IP) IP20 (with lid open) IP21 (with lid closed)
Relative humidity 5% to 95% RH non-condensing
Mechanical shock 40G shock rating