HP Agilent 84110EM Pre Compliant EMC System

HP Agilent 84110EM  Pre Compliant EMC System
Enlarge Image
Request Quote Print Page
Datasheet Other1

Also see HP / Agilent 84115EM

Consisting of the following components:


HP / Agilent 8591EM EMC Spectrum Analyzer, 9kHz-1.8GHz

HP / Agilent 11947A Transient Limiter


Protects spectrum analyzer input from damage caused by high level transients from LISNs ( Line Impedance Stabilization Networks ) during EMI testing.

 

Features:

  • Frequency Range: 9 kHz to 200 MHz
  • Insertion Loss: 10 dB
  • Maximum Input Level: 2.5 W (+34dBm) continuous; 10kW for 10µS Peak; ±12 VDC

 

HP / Agilent 11945A-E51 Close Field Probe Kit with Preamp
  • Designed to measure magnetic-field radiation from surface currents, slots, cables, and ICs for EMC diagnostic and troubleshooting measurements.
  • Operates from 9 kHz to 1 GHz
  • Comes with a 2-meter RG-223 coaxial cable and SMA (f)-to -type-N (m) adapter, and an SMA (f)-to-BNC (m) adapter for each probe.
  • Option E51 adds the HP / Agilent 8447F Option H64 dual preamplifier (or HP / Agilent 11909A preamplifier), a 36-inch  (914-mm) type-N cable, and a carrying bag for storage and protection of the entire set.

 

HP / Agilent 11955A ( EMCO 93110 ) Biconical Antenna

Features:

  • Frequency Range: 30 MHz to 300 MHz
  • Max Continuous Power: 0.5 W
  • VSWR (avg): 1.8 : 1
  • Impedance: 50 ohms
  • Connector: type N female
  • Mounting Base: 1/4 inch x 20 female thread

 

HP / Agilent 11956A ( EMCO 93146 ) Log Periodic Antenna

Features:

  • Frequency Range: 200 MHz to 1 GHz
  • Max Continuous Power: 1 kW
  • Impedance: 50 ohms
  • Connector: type N female
  • Mounting Base: 1/4 inch x 20 female thread

 

HP / Agilent 11968C ( EMCO TR-3 ) Tripod

Features:

  • Non-metallic to minimize unwanted reflections from test environment

 

HP / Agilent 11967D ( EMCO 3810/2 ) LISN / PLISN

Multi-line low pass filter networks used for conducted emissions measurement.  They are placed between the power mains and the EUT ( Equipment Under Test ) to stabilize line impedance, provide a 50 ohms RF connection, and eliminate unwanted RF signals from the line supply.   Designed to be used with a signal analyzer for making FCC 15, VDE 0871 & 0875, and EN55022 conformance measurements.

An Artificial Hand circuit which conforms to EN55014 is included.  The circuit is useful for testing hand-held equipment which does not have a connection to protective earth ground.

 

Features:

  • Frequency Range: 9 kHz to 30 MHz
  • Continuous Current Rating: 10A
  • Earth Line Choke
  • Artificial Hand Network