DSP Measurement Technique: |
Transit time measurement with a sampling resolution of 50 pico/second, with a continuous signal level indication to the display. |
Flow Velocity Range (Bi-directional): |
Minimum velocity 0.1m/s
Max velocity 20m/s |
Flow Measurement Accuracy: |
±0.5% to ±2% of flow reading for flow rate >0.2m/s and Pipe ID >75mm
±3% of flow reading for flow rate >0.2m/s and Pipe ID in range 13mm - 75mm
±6% of flow reading for flow rate < 0.2m/s
Flow velocity corrected for Reynolds number over entire velocity range |
Repeatability: |
±0.5% of measured value or ±0.02m/s whichever is the greater |
Response Time: |
< 500ms depending on pipe diameter |
Selectable Flow Units: |
VELOCITY: m/sec, ft/sec
VOLUME: l/s, l/min, l/h, gal/min, gal/h, USgals/min, USgals/h, Barrel/h, Barrel/day, m³/s, m³/min, m³/h |
Selectable Volume Units: |
l, gal, USgals, Barrel, m³ |
Total Volume: |
12 Digits - forward and reverse |