Power Trend 3010 AC Dropout/Burst Simulator, 50/ 60 Hz

Trend 3010 AC Dropout/Burst Simulator, 50/ 60 Hz
Request Quote Print Page
Specifications

 

Specifications:

AC Line Voltage 95-130 Vac or 190-260 Vac, 50/60 Hz single phase. Change the line voltage range on the interior terminal strip
Load Current 30 amps rms maximum at 115 Vac and 10 amps at 230 Vac
AC Dropout Range 0-500 cycles continuously adjustable using the Preset switch and Variable control
Burst Range 0-499.5 cycles, with 0-180° turn-on delay
Variable Dial range is 0-10 ms. Accuracy is ±3% of full scale. Dropouts and bursts begin on the negative-to-positive line voltage transition
Triggering Manual and autotriggering is provided. Use the Delay knob to adjust the retriggering rate from approximately 0.2 to 12 seconds, as measured from the end of one event to the beginning of the next
Sync Output Generates a positive TTL-level pulse for triggering an external monitor scope
Monitor Output Produces an output pulse equal in length to the preset interval ± the variable dial setting
AC Connectors The standard model 3010 is wired for 115 Vac and fitted with NEMA L5-30 twistlock plug and receptacle. Alternative electrical devices are also available
Temperature Range 0 - 40 ± C ambient range
Dimensions (H x W x D) 3.38 x 9.68 x 6.75 in. (85.9 x 245.9 x 171.5 mm). Weight: 4.5 lbs (2 kg)