Tektronix 2465A 4 Channel Portable Analog Oscilloscope 350 MHz

Rent Tektronix 2465A 4 Channel Portable Analog Oscilloscope 350 MHz
Enlarge Image
Tektronix Test Equipment 2465A
Request Quote Print Page
Datasheet
4 Ch, 350 MHz Oscilloscope
 
Options:
  • Option 01: Digital Multimeter
  • Option 05: TV Waveform Measurement System
  • Option 06: Counter/Timer/Trigger
  • Option 09: Counter/Timer/Trigger and Word Recognizer
  • Option 10: IEEE-488 GPIB Interface
 
Tektronix Test Equipment 2465A Features
Vertical System
  • Display Modes: CH1, CH2, CH3, CH4, Add (CH1 + CH2); Invert (CH2 only); Alternating and Chopped display
  • Channel 1 and Channel 2
    • Deflection Factor: 2 mV/div to 5 V/div
    • Frequency Response (-3 dB Bandwidth): 350 MHz
    • Step Response: ≤ 1 ns (Rise times calculated from tr=0.35/BW)
    • Input Z: 1 Mohm or 50 ohm
  • Channel 3 and Channel 4
    • Deflection Factor: 100 and 500 mV/div
    • Frequency Response: same as Channel 1 and Channel 2
    • Input Z: 1 Mohm
  • Horizontal System
    • Display Modes: A (main sweep), A INTENsified, ALTernate A Intensified with B (delayed sweep) and B. In X-Y mode, Channel 1 provides X-axis (horizontal) deflection
    • A Sweep Time Base Range: 500 ms/div to 5 ns/div in a 1-2-5 sequence of 25 steps (X10 magnification extends fastest sweep rate to 500 ps/div
    • B Sweep Time Base Range: 50 ms/div to 5 ns/div in a 1-2-5 sequence of 22 steps (X10 magnification extends fastest sweep rate to 500 ps/div)
    • DT Readout Resolution: either 10 ps or 0.025% of full scale, which ever is greater
    • DT Range-With Cursors: ±10 times the A Sec/div setting
    • Sweep Delay Range: 0 to 9.95 times the A Sec/div setting for settings from 500 ms/div to 10 ns/div
  • Triggering
    Trigger Modes from CH1 or CH 2 Source: DC Coupled; Noise Reject Coupled; HF Reject Coupled; LF Reject Coupled; AC Coupled
  • X-Y Operation
    • X-Axis Deflection Factor Range, Variable Range and Accuracy - Same as Channel 1
    • X-Axis Bandwidth - DC to 3 MHz
  • Cursor and Front-Panel Display Cursor Position Range: DVolts: At least the center 7.6 vertical divisions. DTime: At least the center 9.6 horizontal divisions
Tektronix Test Equipment 2465A Specs
  • 350 MHz Bandwidth
  • 1 ns Rise Time
  • Auto Setup
  • Save and Recall Setups
  • Set-up Sequencing
  • On-Screen Trigger-Level Readout
  • Volts and Time Cursors with On-Screen Readout
  • Cursors After Delay
  • Four Independent Channels
  • Switchable 1 Mohm and 50 ohm Inputs