Teseq NSG 3040-SOW Slow Oscillating Waveform Generator

Rent Teseq NSG 3040-SOW EMC Generator for Surge, EFT and PQT for EC/EN 61000-4-18 and ANSI C37.90.1
Enlarge Image
Rent Teseq NSG 3040-SOW EMC Generator for Surge, EFT and PQT for EC/EN 61000-4-18 and ANSI C37.90.1 Rent Teseq NSG 3040-SOW EMC Generator for Surge, EFT and PQT for EC/EN 61000-4-18 and ANSI C37.90.1 Rent Teseq NSG 3040-SOW EMC Generator for Surge, EFT and PQT for EC/EN 61000-4-18 and ANSI C37.90.1
Teseq (Schaffner) NSG3040-SOW
Request Quote Print Page
Datasheet Accessory Kit

Teseq’s new NSG 3040-SOW is an easy-to-use stand alone generator for Slow Damped Oscillatory Wave testing (100 kHz and 1 MHz) in compliance with IEC/EN 61000-4-18 and ANSI C37.90.1, for single phase equipment up to 270 V/16 A. Unique NSG 3040-SOW capabilities enable users not only to perform tests according to exact standard requirements, but also to test at higher levels when over-testing is required, and to test under conditions that are closer to reality, ensuring their product will perform as intended in the real world. Unique NSG 3040-SOW capabilities include higher voltage levels (up to 4.4 kV) ideal for development and over-testing purposes. Common mode, differential mode, and single/multiple line to ground coupling. Unique NSG 3040-SOW source impedance values that refl ect actual reality conditions. The NSG 3040-SOW features a selectable source impedance of 200 Ω and 150 Ω. According to standard, 200 Ω is the fi xed output impedance, while the 150 Ω value represents the actual impedance of cables (twisted pairs).


Features:

 
  • IEC/EN 61000-4-18 & ANSI C37.90.1 compliant
  • 100 kHz and 1 MHz oscillation frequency from 0.2 to 4.4 kV
  • Selectable source impedance of 200 Ω and 150 Ω
  • Pulse repetition rate exceeds standards requirement
  • Quickly launch tests from extensive Standards Library or User Test folders
  • Easy-to-operate 7“ touchscreen color display
 

Specifications:

 
Voltage Range 0.2 to 4.4 kV
Oscillation Frequency 100 kHz and 1 MHz
Pulse Repitition 1 MHz pulse: From 1/s to 600/s 1), default is 400/s
100 kHz pulse: From 1/s to 120/s 1), default is 40/s
Source Impedance 150 Ω and 200 Ω
Burst Duration From 1 s to 100 s or 1 pulse to 9999 pulses or continuous – default setting is 2 s
Rise Time 75 ns
EUT AC 1 Ph 16 A, 24 to 270 Vrms, 50/60 Hz (phase - neutral), 400 Hz max.
EUT DC 16 A, 0 to 270 VDC
Coupling Cap 0.5 μF
Decoupling Choke 2 x ≤1.5 mH
Output Floating

 

Options:
 
WIN 3000 Control and reporting software
MD 200 Voltage calibration probe
MD 300-SOW Current calibration probe
CDN 3425 Capacitive coupling clamp
INA XXX Adapter for capacitive coupling clamp
INA 166 Rack mounting brackets (4HU)