The Schaffner NSG2070 100 kHz - 250 MHz, IEC61000-4-6 Test System is a simple, self-contained, self-calibrating system for fast, effective, reliable testing for susceptibility to induced RF in power lines and data lines for both compliance testing and pre-compliance characterisation. The system fulfills all the requirements of IEC 61000-4-6. The NSG 2070 is compatible with all types of power line and data line coupling options; namely coupling/decoupling networks, electromagnetic clamp and current injection probe.

 

Amplifier Specifications (PRE-AMP INPUT, RF-OUTPUT):

 
Bandwidth 100 kHz to 250 MHz
Output impedance 50Ω Load
VSWR 1:1 up to infinity (no deterioration or ringing)
Distortion < -20 dB (relative to carrier frequency)
Power output 85 W max. (+10 dBm)
Linearity ±1.5 dB, with calibration < ±0.5 dB
Input sensitivity -40 dBm to +10 dBm (Pre-amp input)
Input impedance 50Ω Input VSWR: < 1.5
Coupling network cable connection row 3 column 2
Cable 50Ω ( ± 1Ω)
Attenuator -4 dB/50Ω, 40 W min.

 

Synthesizer Specifications (PRE-AMP output):

 
Sweep modes linear, numeric, percentage
Output impedance 50Ω VSWR: < 1.5
Distortion < -20 dB (referred to carrier freq.)
Output range -40 dBm to +10 dBm
Amplitude modulation 0 to 100 %, 80 % ≤ +5 %
Modulation frequency 1 kHz ±1%
Operating modes frequency sweep, pulse mode, manual operation
Linearity < +2 dB, calibrated < ±0.5 dB
Hold time 2 ms to 100 sec
Dynamic range > 58 dB
 


RF - Input Specifications:

 
Frequency range 100 kHz to 250 MHz
Input impedance 50Ω
Input voltage max. 5 V
RF-input fuse-protected