Pulse form: |
5/50 ns ±30% (50 Ω / 1 kΩ) |
Pulse amplitude: |
200 V to 4.8 kV ±10% (open circuit) |
Pulse polarity: |
+, -, alternating |
Pulse output impedance: |
50 Ω ±20% |
Burst frequency: |
0.1 kHz to 1 MHz ±2% |
Spikes per packet: |
1 to 255 |
Continuous frequency: |
Up to 10 kHz |
Burst repetition: |
20 ms to 100s ±2% |
Phase angle: |
Asynchronous or synchronous 0 - 360° ±2% |
Statistical freq. distribution: |
Within selectable limits of burst frequency |
Internal coupling network: |
Single phase, in accordance with IEC 61000-4-4 |
EUT supply: |
250 V/16 A ac or 120 V/16 A dc max. |
EUT connection: |
IEC 320 C20 |
Instrument power supply: |
100 - 240 V, 50/60 Hz |
Weight: |
12.5 kg approx. |
Coupling modes: |
L1, N, PE (and combination) - to reference ground functions for the automation, interleaved |
CAS 3025 BURST/EFT PULSE VERIFICATION KIT:
The Teseq CAS 3025 burst/EFT pulse verification kit has been specially designed to comply with the new requirements of IEC/EN 61000-4-4: amendment 2: 2001 to enable EMC engineers to verify their burst/ EFT test generators periodically.
The Teseq CAS 3025 comprises two termination attenuators – INA 265A and INA 266 – plus a coaxial RG58 cable and calibration certificate indicating the precise ratio.
INA 265A termination/attenuation (typical): |
50 Ω; 1:1000 |
INA 266 termination/attenuation (typical): |
1000 Ω; 1:2000 |
Bandwidth: |
400 MHz |
Max. input burst peak voltage: |
8800 V peak |
Operating temperature: |
-10 to +40°C |
Dimensions L x W x H: |
280 x 230 x 85 mm |
Weight: |
900 g approx. |