Teseq NSG 3060 Transient Generator


Need Help? Call (800) 404-2832ATEC AssuranceWorldwide Delivery
Teseq NSG 3060-1 Conducted Immunity Generator with added modules
Enlarge Image
Teseq NSG 3060-1 Conducted Immunity Generator with added modules Teseq NSG 3060-1 Conducted Immunity Generator with added modules
Teseq NSG3060
Request Quote Print Page
NSG3060 Datasheet Accessory Kit
The Teseq NSG 3060 Multi-Function Generator generates surge voltage to 6.6 kV and emits an EFT/Burst pulse of up to 4.8 kV/1 MHz. Teseq NSG 3060 devices simulate electromagnetc interference effects for the purpose of immunity testing in compliance with manufacturer, national and international standards. TheTeseq NSG 3060 6.6 kV is designed to fulfill requirements for CE mark and ANSI C62.41 testing, including Combination wave, Ring wave and EFT pulses as well as PQT. Extensive expansion capability enables the system to be configured for a much broader range of applications, also fulfilling standards such as IEC 61000-4-5, -4-12, -6-5 and EN 61000-6. The architecture of the units allow individual pulse modules to be calibrated separately; calibration data and correction factors can be stored on the controller. The 7" color TFT display featurs a touchscreen interface, a wheel with step size keys and large, start-stop-pause keys. 
 
Teseq NSG3060 Features
  • Modular, expandable system
  • Surge voltage to 6.6 kV for overtesting
  • Easy to use 7" color touch screen
  • IEC and ANSI coupling methods
  • DTA (Direct Test Access) provides fast standard test settings
  • Parameters can be changed while test is running
  • Wide range of optional test accessories
  • High accuracy switching technology meets ANSI coupling requirements
Teseq NSG3060 Specs

Surge Combo Wave Pulse

Pulse Conforms to IEC/EN 61000-4-5 and ANSI (IEEE) 62.41
 
Parameter Value
Pulse voltage (open circuit) 200 V to 6.6 kV (in 1 V steps)
Pulse current (short circuit) 100 A to 3.3 kA
Impedance 2/12 Ω
Polarity Positive / negative / alternate
Pulse repetition 10 s, up to 600 s (in 1 s steps)
Test duration 1 to 9999 pulses, continuous
Phase synchronization Asynchronous, synchronous 0 to 359º (in 1º steps)
Coupling ANSI / IEC / External 
 

Burst (EFT) 5/50 ns

Pulse conforms to IEC/EN 61000-4-4
 
Parameter Value
Pulse amplitude 200 V to 4.8 kV (in 1 V steps) - open circuit
100 V to 2.4 kV (50 Ω matching system)
Burst frequency 100 Hz to 1000 kHz
Polarity Positive / negative / alternate
Repetition time 1 ms to 4200 s (70 min)
Burst time 1 µs to 1999 s, single pulse, continuous
Test duration 1 s to 1000 h
Phase synchronization Asynchronous, synchronous 0 to 359º (in 1º steps)
Coupling ANSI / IEC / External
 

PQF Dips & Drops

Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
 
Parameter Value
Dips & Interrupts From EUT voltage input to 0 V, 0%
Uvar with optional variac Depending on model (VAR 3005)
Uvar with step transformer 0, 40, 70, 80% (INA 650x)
Peak inrush current capability 500 A (at 230 V)
Switching times 1 to 5 μs (100 Ω load)
Event time 20 µs to 1999 s, 1 to 99’999 cycles
Test duration 1 s to 70’000 min, 1 to 99’999 events, continuous
Repetition time 40 µs to 35 min, 1 to 99’999 cycles
Phase synchronization Asynchronous, synchronous 0 to 359º (in 1º steps)
Options:
 
CDN 3061-C16-PQM Surge, Ringwave, EFT/Burst, Dips and Drops for 4-11
CDN 3063-C32 Combined surge & burst coupling network for
480 VAC Ph-Ph, 32 A
CDN 3063-C63 Combined surge & burst coupling network for
480 VAC Ph-Ph, 63 A
CDN 3063-S100 Coupling network 3-ph, 480V, 100A Automatic
CDN 3083-S100 Surge coupling network for 3 Phase, 100 Amp, 690 Volt
CDN 8014 / CDN 8015 Capacitative coupling clamp for burst
CDN 163 Burst coupling network 100 A per phase
(coupling all to ref ground)
CDN 117/ CDN 118 Coupling networks for signal-/data lines (surge)
CAS 3025 Burst/EFT verification set
MD 200A Voltage differential probe 7 kV
MD 300 Current probe 5 kA
INA 702 Magnetic Field Coil
MFO 6502 Automatic Power Line Frequency Magnetic Field

How to Video: Teseq NSG 3060 Conducted Immunity Transient Generator