The Valhalla 2100 AC/DC Wideband Digital Power Analyzer is a wideband digital power analyzer boasting twin high resolution digital displays, DC to 20 KHz frequency response, true power measurement, true RMS voltage and current and built-in peak overload indicators.
The wideband direct-coupled, front-end design permits it to make accurate power measurements even in the most difficult applications. Switching power supplies, SCR controlled circuits and pulsed DC devices are just a few of the applications requiring the true power measurement capability of the Valhalla 2100.
Specifications
Range/Resolution Table
True RMS Voltage | True RMS Current |
.2000A | 2.000A | 20.00A |
150.00V | 30.00W | 300.0W | 3000W |
300.0V | 60.00W | 600.0W | 6000W |
600.0V | 120.00W | 1200.0W | 12000W |
| True WATTS |
Specifications
AC/DC Current (True RMS) |
Crest Factor Response | 50:1 for Minimum RMS input, linearly decreasing to 2.5:1 for full scale RMS input |
Peak Indicator | Illuminates at 2.5 x full scale |
Minimum Input | 5% of range |
Maximum Input | 35 A peak, 20 A DC or RMS; 100 A DC or RMS for 16 ms without damage |
Overrange | 150% of full scale for DC, up to maximum input |
AC/DC Voltage (True RMS) |
Crest Factor Response | 50:1 for minimum RMS input, linearly decreasing to 2.5:1 for full scale RMS input |
Minimum Input | 5% of range |
Maximum Input | 600 VDC or RMS AC, 1500 V peak |
Maximum Common Mode | 1500 V peak, neutral to earth |
Peak Indicator | Illuminates at 2.5 x full scale |
Watts (True Power - EI COS Ø) |
Power Factor Response | Zero to unity leading or lagging |
Accuracy | (V-A-W 25°C ±5°C, 1 Year) |
DC & 40 Hz to 5 kHz | ± 0.25% of reading ± 6 digits |
5 kHz to 10 kHz | ± 0.5% of reading ± 0.5% of range |
10 kHz to 20 kHz | ± 1% of reading ± 1% of range (2A range only) |