Test Burst Rate |
Manual one-shot, plus continuously variable from <20 bursts per second to >120 bursts per second, plus 60 Hz or 120 Hz synchronized with power line. Phase or burst is adjustable through >320° with respect to power-line frequency, plus external trigger one-shot to 120 bursts per second. |
Test Duration |
Continuously adjustable from <2 seconds to >10 seconds by front panel control, plus a front panel indicator for test in progress |
Output Isolation |
Output Isolation is provided on the inner conductors of two type UG-931 High-Voltage Connectors. Output may be directly applied to any power line voltage up to 500 Vrms |
Shielding |
Transient burst signal generator is fully shielded to prevent unwanted radiation or conduction of signal |
Monitor Output |
A low-level 1000:1 attenuated output referenced to ground is provided for scope monitoring |
Trigger Output |
A front panel scope trigger output signal is provided, which is present prior to turning the high voltage on |
High Voltage |
Two push buttons (located on opposite sides of the instrument) must be simultaneously pushed in order to obtain high voltage output |
Input Voltage |
115V±10%, 60 Hz |
Input Power |
100W |
*Specifications subject to change without notice