Frequency Modes:
0 - 50 kHz span:
The selected measurement is performed over the range of 0 - 50 kHz
Start to 0 Hz:
The selected measurement is performed over the range defined by the SPAN control with a start frequency of 0 Hz.
About Start:
The selected measurement is performed over the range defined by the SPAN control with constant start frequency.
About Center:
The selected measurement is performed over the range defined by the SPAN control with constatn center frequency.
Frequency Range:
0.02 Hz to 50 kHz
Frequency Spans:
2 Hz to 50 kHz in 2 - 5- 10 sequence, except 25 kHz span is available instead of 20 kHz. Same spans are available in all frequency modes.
Display Modes: Linear:
Linear or log frequency axis
Frequency Accuracy:
The center frequency of each calculated line is accurate to ±0.001%
Frequency Resolution:
Standard:
Cursor resolution is limited by the calculated line spacing for the selected span and operating mode. Cursor frequency readout worst case error is ±0.5% or ±0.25% of span, depending on span and processing mode.
Improved Accuracy: