Yokogawa 2533E31 AC Digital Power Meter

Yokogawa 2533E31 AC Digital Power Meter
Enlarge Image
Request Quote Print Page
Datasheet

Features:

  • Simultaneous Display of 3 Measured Values
  • High Precision
  • Wide Band of DC 10 Hz to 30 kHz
  • Abundant Computing Functions are Incorporated
  • PT and CT Sealing
  • Analog Output is Standard Equipment


Specifications:

Rated Input Voltage Ranges: 30/60/150/ 300/600 V
Current Ranges: AC: 0.5/1/2/5/10/20 A
DC/AC: 1/2/5/10/20 A
Frequency Ranges: AC: 10 Hz to 30 kHz
DC/AC: DC, 10 Hz to 30 kHz
Crest Factor AC Voltage: Max. 2
AC Current: Max. 3
DC/AC Voltage: Max. 2
DC/AC Current: Max. 3 or 50 A (peak)
Principle Voltage: Change of mean value rectification and true RMS by LOG-anti LOG
Current: True RMS by LOG-anti LOG
PWM time division multiplication
Accuracy ±0.1% of reading +0.1% of range
Influence By Power Factor Within 50/60 Hz ±0.5% of reading at cos=0.5