  • Frequency Range, 100 kHz to 100 GHz (sensor dependent)
  • Power Range 0.1 nW (-70 dBm) to 5 W (+37 dBm) sensor dependent
  • Dual Sensor Simultaneous Power Measurements (optional)
  • 20 Measurements per Second
  • Stored Calibration Data for up to 8 Sensors
 

Specifications:

  • Frequency Range: 100 kHz to 100 GHz, sensor dependent.  Refer to the Power Meter Sensor section
  • Power Range: (Display calibrated in mW, WW, nW, dBm, and dB relative to selected reference); -70 dBm to +37 dBm (0.1 nW to 5W), sensor dependent
 

Power Reference:

  • Source: Internal 50 MHz oscillator with Type N female connector on front panel
  • Power Output: 1.00 mW
  • Calibration Factors: 3.0 dB to -3.0 dB range in 0.01 dB steps
  • Ranging: Autoranging plus hold on range
  • Setting Time: Diode and millimeter wave sensors, typically 0.2 to 0.5s except 1.35 to 2.5s on the lowest range.  Thermocouple sensors, typically 0.5 to 6s
 

Recorder Output:

  • Watt Mode: 10 volts full-scale, proportional to indicated power over each range
  • dB Mode: 8 volts equivalent to 0 dBm.  Sensitivity of 1 volt per 10 dB change over the entire dB range of sensor
  • Display: 4 digit LED, 3½ digit display of power, 4 digit display of dB with 0.01 dB resolution.  Auxiliary analog display, uncalibrated, proportional to recorder output
  • Limits: Entered through front panel in dB only, operable in both dB and power modes
  • Annunciators: LEDs indicate mW, µW, nW, dBm or relative dB (dBr); use of channel 1 (CH1), channel 2 (CH2, option -03) and channel 3 (CH3 = CH1 - CH2 in dB); out of dB limits; and condition of GPIB activity (LSN, ATN, REM, TLK, option -01B)
 

Power Sensors

Diode Sensors:
Model
(Impedance)
(RF Connector)
Frequency Range Dynamic Range (dBm) Overload Rating
(Watts)
(dBm)
51011 (4B)
50 ohm
N(M)
100 kHz to 12.4 GHz -60 to +10 300 mW
+25 dBm
51012 (4C)
75 ohm
N(M)
100 kHz to 1 GHz -60 to +10 300 mW
+25 dBm
51012-S/4 (4C)
75 ohm
N(M)
100 kHz to 2 GHz -60 to +10 300 mW
+25 dBm
51013 (4E)
50 ohm
N(M)
100 kHz to 18 GHz -60 to +10 300 mW
+25 dBm
51075
50 ohm
N(M)
100 kHz to 18 GHz -60 to +10 300 mW
+25 dBm
51051 (4G)
50 ohm
APC 3.5 (M)
1 MHz to 26.5 GHz -60 to +10 300 mW
+25 dBm
51015 (5E)
50 ohm
N(M)
100 kHz to 18 GHz -50 to +20 2 W AVG.
+33 dBm
51033 (6E)
50 ohm
N(M)
100 kHz to 18 GHz -40 to +30 2 W AVG.
+33 dBm
51071
50 ohm
K(M)
10 MHz to 26.5 GHz -60 to +10 300 mW
+25 dBm
51072
50 ohm
K(M)
30 MHz to 40 GHz -60 to +10 300 mW
+25 dBm


Thermocouple Sensors:
Model
(Impedance)
(RF Connector)
Frequency Range Dynamic Range (dBm) Overload Rating
(Watts)
(dBm)
51100 (9E)
50 ohm
N(M)
10 MHz to 18 GHz -20 to +20 300 mW
+25 dBm
51101
50 ohm
N(M)
100 kHz to 4.2 GHz -20 to +20 300 mW
+25 dBm
51102
50 ohm
K(M)
50 MHz to 26.5 GHz -20 to +20 300 mW
+25 dBm


Options: 

(please consult your sales representative on availability)

  • -01B IEEE-488 Bus Interface
  • -03A Second Input Channel