Illuminating / viewing system | dl8 (diffuse illumination 8° viewing angle); SCI (specular component included) Meets IS0 772411 and DIN 5033 teil 7 for d/8 geometry; also meets CIE recommendations for dl0 geometry and ASTM E l 164 standards for t10 geometries |
Detector | Silicon photodiode array with spectral filter array |
Wavelength range | 400 to 700nm |
Wavelength pitch | 20nm |
Half bandwidth | 20nm |
Photometric range | 0 to 175% reflectance |
Light source | Pulsed xenon arc lamp |
Minimum interval between measurements | 3 seconds |
Battery performance | Alkaline manganese: Approx. 2000 measurements at 10-second intervals |
Illumination / measurement area | θ30mm illumination l025mm measurement (Measurement aperture is θ 30mm) |
Repeatability | Spectral reflectance: | Standard deviation within 0.20% |
Colorimetric values: | Standard deviation within ΔE*ab 0.05 |
Measurement conditions: | White calibration plate measured 30 times at 10-second intervals after white calibration was performed |
Measurement and calculation time | 2.0 seconds to display of results (except Munsell and automatic selection of target value) |
Display | 121 - character x 7-line (128x56-dot) dot-matrix LCD with adjustable contrast |
Measuring modes | Single measurement / automatic averaging of multiple measurements |
Interface | RS-232C standard, 9-pin female D-subminiature connector Communication parameters: Baud rate: 1200, 2400, 4800, 9600, 19200bps Character length: 8 bits Stop bits: 1 bit Parity: NONE Manual mode: Measurement data can be output (for each measurement at time of measurement; for all selected measurements stored on memory card) REMOTE mode: Command input, data output, input of messages for display only Comment can be input using bar code reader |
Display data | Spectral reflectance: Graph or numerical values Colorimetric values: Numerical absolute color and/or color difference values in the following notations: XYZ, Yxy, L*a*b*, L*C*h, Hunter Lab, Munsell, MI (Metamerism Index), CMC (f:c), WI (ASTM E313), WI (CIE), YI (ASTM E313), YI (ASTM D1925), IS0 Brightness (IS0 2470) IS0 Status A and Status T densities Data or messages transmitted from a computer connected to the RS-232C terminal can also be displayed in REMOTE mode. |
Measurement conditions | Illuminant: CIE Standard llluminants A, C, D50, and D65; Fluorescent llluminants F2, F6, F7, F8, F10, F l l (TL84), and F12 (Ultralume 3000) 2 illuminants can be selected. Observer: CIE 2' and 10' Standard Observers Measurement conditions stored on installed optional memory card given priority. |
Data memory | Built-in memory: Up to a total of 200 sets of data (measurement and target color) including a maximum of 199 sets of target color data With optional 128KB memory card: Up to a total of 1350 sets of data including a maximum of 1349 sets of target color data With marketed 256KB SRAM card: Up to a total of 2700 sets of data including a maximum of 2699 sets of target color data |
Target color data | Target color data can be set by measurement, by data input using keys, or by data input from computer connected to RS-232C terminal Target color data can be temporarily deleted and later recovered. Automatic target color selection function determines which target color is closest to measured color |
Tolerance data | Upper and lower limits for color difference values in the following color spaces: XYZ, Yxy, L*a'b*, Hunter Lab, L*C*h, MI, CMC (l:c), Wl (ASTM E313), WI (CIE), Yl (ASTM E313), YI (ASTM D1925), IS0 Brightness (IS0 2470) Upper and lower limit values can be set independently. |