This oscilloscope probe is an accessory and is only available to rent with an oscilloscope.
See All Oscilloscopes
The LeCroy HFP1000 High Frequency Probe 1 GHz, with its small, low mass probe head, is designed for ease of use and high performance. The probe tip socket fits easily onto 0.025 inch square pins for direct access to test points. Several different adapters are available which connect directly in the probe socket. The probe tip socket has a removable tip cartridge for easy replacement in case the probe socket gets damaged. The ground socket will accept several different ground leads to provide a short ground path for high frequency performance. The AutoColor ID consists of an LED inside the probe head which illuminates the probe body in the default trace color of the channel to which the probe is connected. The AutoColor ID will only function when the probe is connected to a Teledyne LeCroy oscilloscope supplied with the ProBus interface.
Features
- Interface: ProBus; complete compatibility with WavePro, Waverunner, and LC-series oscilloscope having firmware version 8.7.0 or higher
- Five Interchangeable tips for probing a variety of test points
- Replaceable probe tip socket
- Hands-free probing with optional FreeHand probe holder
- AutoColor ID feature matches the probe color to the trace color
- Probe Head Size: Length 61mm (2.4in), Width 7.3mm (0.29in), Height 13.1mm (0.52in)
- Cable Length: 1.3m (51.1in)
Specifications
Bandwidth: | 1 GHz |
Input Capacitance: | 0.7 pF |
DC Input Resistance: | 100kΩ |
Input Dynamic Range: | ±8 V |
Maximum Input Voltage: | 40V1 |
Intended Output Load: | 50Ω |
Attenuation: | 10:1 ±1% |
Output Zero: | ≤4mV, referred to input |
Offset Accuracy: | ±(1% of offset value +4mV) |
Output Connector: | ProBus |