Related Products
High Voltage Inc. VLF-90CMF High Voltage VLF Hipot Tester
- 90 kV peak output
- For testing cables rated to 69 kV
- Input: 230 V, 50/60 Hz, 20A peak, 15A average
High Voltage Inc. VLF-12011CMF
- 0 - 120 kVac peak output
- For testing cables rated to 115 kV
- Input: 230 V, 50/60 Hz, 30A peak, 25A average
Megger VLF Sinus 62 kV Cable Tester
- 0 - 62 kV peak output
- For testing cables rated to 35 kV
- Integrated tan delta testing
High Voltage Inc. VLF-65E VLF Hipot Tester
- 0 - 65 kV Peak, 46 kV RMS @ 28 mA
- For testing cables rated to 35 kV
- Tan delta testing with add-on
Megger IDAX300 Insulation Diagnostic Analyzer
- Fast and accurate moisture assessment in power transformers
- Well proven technology; IDAX300 units have been in field use for more than 10 years
- Reliable results at any temperature
High Voltage Inc. VLF-34E VLF Hipot Tester
- 0 - 34 kV Peak, 24 kV RMS @ 7 mA
- For testing cables rated to 25 kV
- Tan delta testing with add-on
Tettex MIDAS 2881 Mobile Insulation Diagnosis & Analysing System
- Dissipation Factor (tanδ) and Power Factor (cosΦ )
- Short Circuit Impedance and Excitation Current
- Additional measuring capabilities like Capacitance, Quality Factor, Frequency, Voltage, Current, Power, Losses, Impedance, Inductance, Reactance, Spectrum Analyzer, Digital Scope and Data Logger
Megger VAX020 High Voltage Amplifier
- Output Current: 50mA (Peak) <50Hz, 30mA <10Hz
- Output Current Voltage: 2kV (Peak)
- Frequency Range: DC - 1kHz
Doble M4100 Power Factor Insulation Analyzer
- 47 - 63 Hz
- 25 V - 12 kV Source Output
- Typical Accuracy: ± 0.005%
Doble M4000 Power Factor/Tan-Delta Instrument
- Totally eliminates substation signal interference with Doble's patented Line Frequency Modulation technology
- Generates its own clean test signal for the most reliable and repeatable results
- The highest power to better replicate in service condition
HV Diagnostics HVA45TD LF/DC Hipot Tester
- High test load capacity of 10 µf
- USB and Bluetooth connectivity
- Automatic, easily programmable test sequences
HV Diagnostics HVA34TD VLF/DC Hipot Tester
- Easy-to-use operator interface
- Integrated Tan Delta measurement system
- Performs automatic and advanced tests
HV Diagnostics HVA28TD VLF/DC Hipot Tester
- 5-in-1 universal high voltage and diagnostic testing system
- Integrated Tan Delta measurement system
- Output current of 0 to 20 mA
HV Diagnostics HVA60 VLF & DC Hipot Tester
- 62 kV peak, 44 kV RMS @ 40 mA
- For testing cables rated to 35 kV
- Input voltage: 110 - 240 VAC ±10% (50/60Hz)
HV Diagnostics HVA 30 4 in 1 Universal High Voltage VLF and DC Hipot Tester
- Smallest, lightest, most advanced universal high voltage test instrument available.
- VLF (0.1Hz), DC, Cable Fault Conditioning (Burning), and Sheath/Jacket Testing modes all included.
- Fully Automatic or manual cable test sequences
Megger EasyTest 20 kV Cable Tester
- Easy to operate
- Configurable test sequences
- Compact, rugged, and lightweight design
Megger DELTA-4310 Power Factor (Tan Delta) Test Set
- Easy to use with automatic and manual operation
- Accurate and repeatable measurement results with high noise suppression for the most extreme conditions
- Lightweight, rugged two-piece design, with unit weights of 14 kg and 22 kg
Megger DELTA 4110 Power Factor Test Set
- Easy to use with automatic and manual operation
- Accurate and repeatable measurement results with high noise suppression for the most extreme conditions
- Lightweight, rugged two-piece design, with unit weights of 14 kg and 22 kg
Megger DELTA 4000 Series 12 kV Insulation Diagnostic System
- Easy to use with automatic and manual operation
- Accurate and repeatable measurement results with high noise suppression for the most extreme conditions
- Lightweight, rugged two-piece design, with unit weights of 14 kg and 22 kg
OMICRON CPC 100 Multi-functional Primary Test System
- Max Output Current (AC): 800A
- Max Output Current (DC): 400A
- Input Voltage: 300V
OMICRON CP TD1 Capacitance & Tan Delta Test Unit
- Compact and rugged all-in-one test set
- Wider frequency range for more sensitivity (15 Hz – 400 Hz)
- Testing at variable frequencies for better condition diagnosis
Megger 670600-1 Resonating Inductor
- Expands the range of capacitance and dissipation factor (PF) for DELTA 4000 units
- Hand-crank tuning wheel
- Core gap gauge that displays position of inductor core
Tettex MIDAS micro 2883 12kV Capacitance, Dissipation / Power Factor / Tan Delta Test Set
- Capacitance, dissipation / power factor testing
- Compact one-box design with only 25 kg / 55 lb
- 12 kV high voltage source
Megger TSX303 TRAX Automatic Switch Box
- Supports WRM up to 16A
- Supports TTR up to 250V
- Reduces "ladder time"
HV Diagnostics PD60-2/TD
- Partial Discharge & Tan Delta Analyzer
- Up to 60 kV peak (0.1 Hz VLF)
- Sensitivity: ≈ 10 pC