The Fluke 5720A Oscilloscope Calibrator is an oscilloscope calibration instrument that meets requirements like ISO 9000, ISO Guide 25, ANSI Z540 as well as safety, nuclear regulatory and environmental quality standards for oscilloscopes up to 600 MHz. Power consumption reads at 250 VA and line voltage is selectable from 100V, 120V, 220V or 240V.

Fluke 5820A calibrators operate with a 5 second or faster settling time and carry flash memory and RAM (random access memory) to record your test results. These calibrators are designed to operate in standard laboratory settings with controlled EM environments. Engineers can choose from two options to enhance the Fluke 5820A's performance as well: calibration can be extended to oscilloscopes up to 2.1 GHz and a five-channel output option facilitates automated calibration.
 
Fluke Calibration 5820A Specs
Warm-up Time Twice the time since last warmed up, to a maximum of 30 minutes
Settling Time 5 seconds or faster for all functions and ranges
Standard Interfaces IEE-488 (GPIB), RS-232
Temperature Performance Operating: 0 °C to 50 °C
Calibration (tcal): 15 °C to 35 °C
Storage: -20 °C to 70 °C
Electromagnetic Compatibility Designed to operate in Standard Laboratory environments where the Electromagnetic environment is highly controlled. If used in areas with Electromagnetic fields > 1 V/m, there could be errors in current output values.
Temperature Coefficient Temperature Coefficient for temperatures outside tcal ±5°C: add 0.1 x 1-year specification/°C
Relative Humidity Operating: <80% to 30 °C, <70% to 40 °C, <40% to 50 °C
Storage: <95%, non-condensing
Altitude Operating: 3,050m (10,000 ft) maximum
Non-operating: 12,200m (40,000 ft) maximum
Safety Designed to comply with IEC 1010-1 (1992-1); ANSI/ISA-S82.01-1994; CAN/CSA-C22.2 No. 1010, 1-92
Analog Low Isolation 20V
EMC Complies with EN 61326-1
Line Power Line Voltage (selectable): 100V, 120V, 220V, 240V
Line Frequency: 47 to 63 Hz
Line Voltage Variation: ± 10% about line voltage setting
Power Consumption 250 VA
Dimensions Height: 17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet on bottom of unit
Width: 43.2 cm (17 in), standard rack width
Depth: 47.3 cm (18.6 in) overall
Weight 20 kg (44 lb)
Fluke Calibration 5820A Accessories
  • 55XX/CASE: Transit case with wheels
  • 5500A/HNDL: Side handle
  • 5800A-7002K: Two Piece Replacement Output Cable Set
  • 5800A-7003K: Five Piece Replacement Output Cable Set
  • 5800A-7004K: Oscilloscope Cal Cable and Accessory Kit
  • 5800A-GHZK: 2.1 GHz Bandwidth Extension Upgrade for existing 5800A Oscilloscope Calibrators (not user installable)
  • 5820A-GHZK: 2.1 GHz Bandwidth Extension Upgrade for existing 5820A Oscilloscope Calibrators (not user installable)
  • PM9581/011: Feed Through Termination, 3W, 50 Ohm
  • PM9584/021: Feed Through T-Piece (matched power splitter), 50 Ohm