Yokogawa 700924 100 MHz Differential Probe

Yokogawa 700924 100 MHz Differential Probe
Enlarge Image
Yokogawa 700924
Request Quote Print Page
Datasheet
With increases in the speed of measured signals in recent years, it has become necessary to make floating measurements over a wide frequency band. The 700924 differential probe lets you make wide-band (100 MHz) differential input measurements by just connecting the probe to the input of a single-end input digital oscilloscope.

Applicable for DL750/DL750P & SL1400


Specifications:

Input type Balanced differential input
Frequency band DC up to 100 MHz (-3 dB)
Input attenuation ratio Switched between 1/100 and 1/1000
Input impedance Approximately 4 MΩ, approximately 10 pF parallel
Gain accuracy ±2% (common mode voltage: 400 V or less)
±3% (common mode voltage: 1000 V or less)
Maximum allowed differential voltage ±350 V (DC + ACpeak) or 250 Vrms (1/100 range)
±1400 V (DC + ACpeak) or 1000 Vrms (1/1000 range)
Maximum common mode input voltage ±1400 V (DC + ACpeak) or 1000 Vrms (both 1/100 and 1/1000 ranges)
Maximum input voltage ±1400 V (DC + ACpeak) or 1000 Vrms (1/1000 range)
Common Mode Rejection Ratio (CMRR) -80 dB (60 Hz), -50 dB (1 MHz)
Output voltage ±3.5 V
Output impedance Used with 1 MΩ input impedance
Power supplies Dry cells, four R6P (SUM-3); when using the AC/DC adapter, use an output voltage of 6 V/200 mA or greater/center plus
Dry cell life Approximately 2 hours under continuous use
External dimensions (approximate) 207 mm x 83 mm x 38 mm¹
Total length Approximately 1.5 meters
Weight Approximately 800 grams (excluding dry cells)
Approved standards EMC: EN55011: 1991 + A1: 1997 + A2: 1996
EN50082-1: 1992
Safety: EN61010-1: 1993 + A2: 1995
EN61010-2-031: 1994