The IEC 61340-3-1 describes the discharge current waveforms used to simulate human body model (HBM) electrostatic discharges (ESD) and the basic requirements for equipment used to develop and verify these waveforms. The IEC 61340-3-1 standard covers HBM ESD waveforms for use in general test methods and for application to materials or objects, electronic components and other items for ESD withstand-test or performance-evaluation purposes. The specific application of these HBM ESD waveforms to non-powered semiconductor devices is covered in IEC 60749-26. The waveforms defined in IEC 61340-3-1 are not intended for use in the testing of powered electronic systems for electromagnetic compatibility (EMC), which is covered in IEC 61000-4-2.