Chroma 61511 AC/DC Power Source, 12kVA

Chroma 61511 AC/DC Power Source, 12kVA
Enlarge Image
Request Quote Print Page
Datasheet

The 61511/61512/61611/61612 AC source models provide the (Master-Slave) parallel operation function, which enable users to extend the AC source power output ability by connecting AC sources in parallel. The maximum allowable number of AC source implemented for the parallel operation is 5 units. Therefore, users can achieve a maximum power output up to 90KVA by combining 5 units of assorted AC source of 18KVA in (Master-Slave) parallel operation mode. The user could also use A615103 Power Stage as an alternative cost effective solution for the parallel operation, by implementing it as slave unit.

 

Specifications:

Output Phase 1 or 3 slectable
Output Rating-AC
Power 12kVA
Each Phase 4 kVA
Voltage
Range 0~150V/0~300V
Accuracy 0.2%+0.2%F.S.
Resolution 0.1 V
Distortion *1 0.3% @50/60Hz , 1%@15~1kHz,1.5%@>1kHz
Line regulation 0.1%
Load regulation *2 0.2%
Temp. coefficient 0.02% per degree from 25°
Max Current (1-phase mode)
RMS 96A/48A
Peak (CF=4) 384A / 192A
Max Current (each phase in 3-phase mode)
RMS 32A / 16A
Peak (CF=4) 182A / 64A
Frequency
Range DC, 15-1.5kHz
Accuracy 0.15%
Phase
Range 0 ~ 360°
Resolution 0.3°
Accuracy <0.8°@50/60Hz
DC Output (1-phase mode)
Power 6kW
Voltage 212V / 424V
Current 48A / 24A
DC Output (3-phase mode)
Power 2kW
Voltage 212V / 424V
Current 16A / 8A
Input AC Power (each phase)
AC type 3-phase, Delta or Y connecting
Voltage range *3 190-250V (Delta: L-L, Y: L-N)
Frequency range 47-63 Hz
Max. current Delta: 80A Y: 70A
Measurement
Voltage
Range 150V / 300V
Accuracy 0.2%+0.2%F.S.
Resolution 0.1 V
Current
Range 128 /32/8 A peak
Accuracy (rms) 0.4%+0.3%F.S
Accuracy (peak) 0.4%+0.6%F.S.
Resolution 0.1 A
Power
Accuracy 0.4%+0.4% F.S
Resolution 0.1 W
Dimensions (H x W x D) 1163 x 546 x 700 mm / 45.78 x 21.5 x 27.56 inch *5
Weight 242.4 kg / 533.92 lbs