The Elgar SW10500-1-3-2 Smartwave System is comprised of one master chassis, one or more slave chassis, a power distribution (PDU) chassis, and an optional input power line filter (required for CE mark). Three separate arbitrary waveform generators enable the Elgar SmartWave System to create independent, complex waveforms on all three phases simultaneously. The Elgar SW10500-1-3-2 Smartwave System is designed to meet waveform requirements including DC content (up to 312V), low distortion (THD 0.25% to 100 Hz), low noise and ripple, plus full compliance testing to EMC standards.
Specifications
Power Factor of Load |
0 lagging to 0 leading |
AC or DC Output Voltage |
to 156 VRMS L-N, range 1; 0 to 312 VRMS L-N, range 2 |
AC or DC Output Current Per Phase: |
13A to 135V in 156V range; 6.5A to 270V in 312V range (per 1750 VA module) Note: Higher currents may be achieved in 10.5-21 kVA systems. |
Crest Factor: |
4.0 (peak output current to RMS output current) |
Output Frequency Range |
DC or 40 Hz to 5 kHz. For output frequencies greater than 1 kHz, the max slew rate allowed is 1 kHz per second. |
Output Power: |
10.5 kVA |
Load Regulation: |
0.025% of full scale voltage for a full resistive load to no load; above 1 kHz, add 0.01%/kHz |
Line Regulation |
(DC, or 40 Hz to 5 kHz): 0.025% of full scale for a 10% input line change |
Voltage Accuracy: |
0.1% of range. Above 1 kHz, add 0.2%/kHz. Add 0.1% of full scale for "AC PLUS DC" mode. Valid for 5 to 156 VRMS and 10 to 312 VRMS at 25C |
Voltage Resolution |
0.05% of full scale |
Frequency Resolution: |
0.01 Hz: 40 Hz to 99.99 Hz 0.05 Hz: 100 Hz to 999.9 Hz 0.5 Hz: 1000 Hz to 5000 Hz |
Frequency Accuracy: |
0.01% at 25C 0.001%/C Phase Accuracy, Phase-to-Phase Balanced Linear Resistive Load: 1, 40 Hz to 1 kHz, plus 1/kHz above 1 kHz |
Balanced Linear Resistive Load: |
1, 40 Hz to 1 kHz, plus 1/kHz above 1 kHz |
Phase Angle Resolution: |
0.1 |