Fluke 87V True RMS Digital Multimeter

Fluke 87V Multimeter
Enlarge Image
Fluke 87V
Request Quote Print Page
Manual Specifications
The Fluke 87V-Ex is the ATEX-certified intrinsically safe version of the most popular meter in the world, the Fluke 87V. Intrinsically safe (I.S.) are protective methods employed in potentially explosive atmospheres. ATEX is the most stringent I.S. standard in Europe for products used in hazardous locations. Certified I.S. tools are designed to prevent the release of sufficient energy to cause ignition of flammable material.
 
Fluke 87V Features
  • Unique function for accurate voltage and frequency measurements on variable speed motor drives (VSDs)
  • Atex 137 safety rating for use in zone 1 and zone 2
  • CAT IV 600 V safety approval for non-Ex industrial environments
  • Large display with bright, two-level backlight makes the 87V-Ex very easy to read
  • Built-in thermometer (probe included)
  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • 4-1/2 digit mode for precise measurements (20,000 counts)
  • Measure up to 1000 V and 10 A (ac/dc)
  • Frequency to 200 kHz and % duty cycle
  • Resistance, continuity and diode test
  • 10,000 μF capacitance range for components and motor caps
  • Min/Max-Average and Peak capture to record transients and variations automatically
  • Relative mode to remove test lead interference on resistance measurements
  • Auto and manual ranging for maximum flexibility
  • Analog bar graph for fast changing or unstable signals
  • Input Alert provides audible warning against wrong use of input jacks
Fluke 87V Specs
Voltage dc Maximum voltage: 1000 V
Accuracy: ± (0.05 % + 1)
Maximum resolution: 10 μV
Voltage ac Maximum voltage: 1000 V
Accuracy: ± (0.7 % + 2) True-rms
Maximum resolution: 0.1 mV
Current dc Maximum amps: 10 A (20 A for 30 seconds maximum)
Amps accuracy: ± (0.2 % + 2)
Maximum resolution: 0.01 μA
Current ac Maximum amps: 10 A (20 A for 30 seconds maximum)
Amps accuracy: ± (1.0 % + 2) True-rms
Maximum resolution: 0.1 μA
Resistance Maximum resistance: 50 MW
Accuracy: ± (0.2 % + 1)
Maximum resolution: 0.1 Ω
Capacitance Maximum capacitance: 9,999 μF
Accuracy: ± (1 % + 2)
Maximum resolution: 0.01 nF
Frequency Maximum frequency: 200 kHz
Accuracy: ± (0.005 % + 1)
Maximum resolution: 0.01 Hz