Solar 8309-5-PJ-100-N Line Impedance Stabilzation Network, 5 μH

Rent Solar 8309-5-PJ-100-N Line Impedance Stabilzation Network
Enlarge Image
Solar Electronics 8309-5-PJ-100-N
Request Quote Print Page
Datasheet
The Solar 8309-5-PJ-100-N Line Impedance Stabilzation Network is for measuring conducted radio interference voltages from active power lines to ground to know the line impedance so that repeatable tests can be made by more than one laboratory. Artificial line impedances are specified in MIL-STD-462, V.D.E., C.I.S.P.R., C22.4, NACSEM 5100, ANSI C63.2 and other EMI  specifications.

The characteristic impedance of the five microhenry LISN brackets the mean value of power line impedance which has been measured by independent researchers. The inductance value in parallel with the 50 ohms of the EMI meter fall between the minimum and maximum line impedance values which have been measured. The mean value would be represented by a twenty microhenry inductor in parallel with100 ohms.

The Solar 8309-5-PJ-100-N LISN uses a series inductor between the test sample and the power source to provide the impedance-versus-frequency characteristic. A coaxial connector with d.c. isolation is provided for connection to the associated frequency selective EMI meter. The power source end of the inductor is bypassed to ground.

Specifications:

Current Amps 100
Inductance μH 5
Line/Ground 50-60 Hz 500
Voltage 400 Hz 240
Circuit Single
Frequency Range 150 KHz- 65 MHz