Solar 7225-1 Line Impedance Stabilization Network (1GHz LISN)

Quote Add-Ons

  Tech Support
(800) 404-2832
ATEC Assurance With Every
Rental
    Worldwide
Delivery
The Solar Electronics LISN 7225-1 Impedance Stabilization Network uses a series inductor between the test sample and the power source to provide the impedance-versus-frequency characteristic. A coaxial connector with d.c. isolation is provided for connection to the associated frequency selective EMI meter. The power source end of the inductor is bypassed to ground. Due to the large current-carrying capability of some LISNs, it is not always practical to use a switch for changing inductance values. Instead, some models are equipped with a high current pin plug-and-jack combination for quickly connecting and disconnecting a network and substituting another.This nylon insulated pin plug and jack arrangement is a safety feature, well isolated from inadvertent short circuits, providing protection to operating personnel. Current ratings up to 200 amperes are available in 50 H styles and 500 amperes in 5 H styles.