Specifications:

  • Frequency Range: 10 kHz to 500 MHz
  • Transfer Impedance: 1.0 to 5.0- ohms above 150 kHz
  • Output Load Impedance: 50 ±j 0 ohms
  • Continuous Signal Current: 40 A
  • Maximum Power Current: 200 A. DC to 400 Hz
  • Maximum Power Voltage: Limited by the conductor under test
  • Peak Pulse Current: 60 A Maximum
  • Probe Circuit: Inserted Primary Toroidal Transformer
  • Connector: Type N, Female