Com-Power LI-350 Line Impedance Stabilization Network 400 MHz

  Tech Support
(800) 404-2832
ATEC Assurance With Every
Rental
    Worldwide
Delivery
The Com-Power LI-350 Line Impedance Stabilization Network (LISN) provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products. The LI-350 is compliant with both RTCA DO-160 and MIL-STD 461F.

The LISN provides defined stable impedance and isolates the EUT from power source influences, thereby providing accurate and repeatable results. The Com-Power LI-350 includes one pair of, separately housed, single-conductor networks, to be installed in series with each current-carrying conductor in a single-phase, dual-phase or DC power system. A second LI-350 pair can be used to accommodate 3-phase power systems (Wye or Delta configurations).

The LI-350 is equipped with Superior Electric SUPERCON shrouded sockets at the mains (power input) and EUT (power output) ports. The matching color-coded plugs for connection to the mains and EUT wiring are included. This LISN uses air-core inductors to prevent saturation and permeability variation. The mounting plate of the LI-350 is left unpainted in order to facilitate connection to earth ground in its installation, which is essential due to high leakage current.