Designed specifically for radiated EMC Testing, this mismatch tolerant Class A amplifier delivers power continuously into the very poor match typically associated with broadband EMC antennas when used at low frequency.
The GaAs Class A design ensures a high reliability, low distortion linear performance across the frequency range. This design also ensures that the amplifier will continue to operate at full power even when presented with an open or short circuit at its output. The use of gallium arsenide technology represents a breakthrough in amplifier design for this frequency range and output power.
This unit is powered from a switched mode power supply for high efficiency, high power factor and wide voltage range operation. The unit is air-cooled with integral fans, and is protected against faulty cooling by excess temperature-sensing. A safety interlock connector is provided, which the user can short circuit to ground, to put the amplifier into standby mode. Front panel indicators are provided to indicated over-temperature and RF interlock operation.
Features
- Class A linear and low distortion design
- High Reliability gallium arsenide technology
- Mismatch tolerant and unconditionally stable
- Wide instantaneous bandwidth
- Typical 2 dB compression data
- Harmonics remain below 20 dBc at actual 1 dB compression point
Specifications
Frequency Range (Instantaneous) |
80 to 1000 MHz |
Rated Power |
275 W minimum (350 W typical 80 MHz to 400 MHz) |
Output power at 1 dB gain compression |
250 W minimum (300 W typical 80 MHz to 400 MHz) |
Gain |
56 dB |
Third order intercept point |
64 dBm |
Gain variation with frequency |
±3 dB |
Harmonics mat 250 W output |
Better than -20 dBc |
Output impedance |
50 Ohms |
Stability |
Unconditional |
Output VSWR tolerance |
infinite any phase |
input VSWR |
2:1 |
RF Connector style |
Type N Female |
Dual Safety interlock |
Two BNC female connectors S/C to mute and O/C to mute |
USB interface |
optional |
Supply Voltage |
184-264 VAC |
(Floating input allows operation across 2 phases) |
Supply Frequency Range |
45 to 63 Hz |
Supply Power |
< 2 KVA (nominal 1.6 kva) |
Mains connector |
IEC320 |
Operating temperature |
0 to 40°C |